SERVICE AND SPECIAL FUNCTIONS
The calibration result from the process of "start calibration" will
be displayed here. This can also be changed here by up/down
buttons. This is the ratio between the input versus the
measured
user weight.
Determines brightness of LEDs. 0 = LED Out
Example: Countdown sounds (3-2-1)
Shows - "Are you sure?" message
Option to ignore all errors related to incline, mostly used for
service testing. Note: Incline errors are logged, but not shown
to the user.
Option to ignore all B Level errors so that the machine
remains usable. Note: B Level errors are logged, but not
shown to the
user.
Used to enable or disable the entire OC protection function.
Having enabled helps correct a speed mis-match issue
(console command speed much higher than actual
measured speed under OC conditions. Also assists in
preventing circuit
breaker tripping
If this parameter is disabled, the console display won't
display the warning messages upon the OC events. The OC
protection
function, however, will still be running to protect the
system.
When the counts of the “0146 OC warning” reaches the