SERVICE AND SPECIAL FUNCTIONS
Table of Contents
Touch / TouchXL Console
65
Troubleshooting Guide
EN ClimbMill
Calibratio
n Result
10 ~ 3000
The calibration result from the process of "start calibration" will
be displayed here. This can also be changed here by up/down
buttons. This is the ratio between the input versus the
measured
user weight.
Top Level
Models
Sub-Level 1
Sub Level 2
Default Value
Values/Range
Notes
Hardware
THUREASC
Brightness
5
0 - 9
Determines brightness of LEDs. 0 = LED Out
THUREASC
Model Type
Refer to PPS. Model Type
THUREASC
ErP Time
OFF
OFF ~ 30
T
Tread Sense
30
30/60/90/Off
THUREASC
Beeper
Keypad
ON
ON/OFF
Keypad sound
THUREASC
Countdown
ON
ON/OFF
Example: Countdown sounds (3-2-1)
THUREASC
Headphon
e Jack
Insert Counts
Current Value
0~999999
THUREASC
Insertions Left
30000 -
Current Value
1000~1000000
Reset Count
Shows - "Are you sure?" message
THUREASC
Keypad
Stuck Check
Enable
Enable/Disable
THUREASC
Notification
Enable
Enable/Disable
TA
Ignore
Incline
Errors
Enable
Enable/Disable
Option to ignore all errors related to incline, mostly used for
service testing. Note: Incline errors are logged, but not shown
to the user.
THUREASC
Ignore
B-
Level
Errors
Enable
Enable/Disable
Option to ignore all B Level errors so that the machine
remains usable. Note: B Level errors are logged, but not
shown to the
user.
T
Supported
Over
Over Speed
Disable
Disable/Enable
Used to enable or disable the entire OC protection function.
Having enabled helps correct a speed mis-match issue
(console command speed much higher than actual
measured speed under OC conditions. Also assists in
preventing circuit
breaker tripping
String Warning
Enable
Disable/Enable
If this parameter is disabled, the console display won't
display the warning messages upon the OC events. The OC
protection
function, however, will still be running to protect the
system.
1
0.5 - 4
When the counts of the 0146 OC warningreaches the
1
0.5 - 2