3. MCLK mode switch
X-SPDIF2 has two modes of MCLK output to suitable for connecting different
devices, The MCLK output frequency when switch on and off as shown in the
following table:
Note: When using with synchronous mode X-sabre pro, please set the switch
to ON.
8
Settings & Usage
Switch Position
OFF
ON
Sample Rate
MCLK
Frequency
MCLK
Frequency
44.1kHz
512fs
22.579MHz
128fs
5.6448MHz
48kHz
512fs
24.576MHz
128fs
6.144MHz
88.2kHz
256fs
22.579MHz
128fs
11.2896MHz
96kHz
256fs
24.576MHz
128fs
12.288MHz
176.4kHz
128fs
22.579MHz
128fs
22.579MHz
192kHz
128fs
24.576MHz
128fs
24.576MHz
352.8kHz
128fs
45.1584MHz
128fs
45.1584MHz
384kHz
128fs
49.152MHz
128fs
49.152MHz
705.6kHz
64fs
45.1584MHz
64fs
45.1584MHz
768kHz
64fs
49.152MHz
64fs
49.152MHz