MA3400 | 20150825
11
Q:How often should I charge the MA3400?
A:LeavetheMA3400 on chargewhen not in use - the MAC02 is a Charger/
Maintainer
and will maintain
the batteries in peak condition longer
MA3400 Battery Removal
The MA3400 internal battery is sealed lead acid battery.
Recycle / dispose of batteries in accordance with the applicable regulations.
Battery Removal Procedure
1. Take clamps and cable assemblies from the housing compartments
2. Gently lever off the side compartment doors from the main housing
3. Place the jump start front side down.
4. Locate and remove the screws on the back
5. Remove rear cover
6.
Disconnect
the internalbattery
connections
fromthe terminals.Preventaccidentalarcingby protecting
the terminal not being removed
7. Lift the battery from out of the enclosure.