The dishes are not clean enough after
washing
* The filter is clogged.
* Unqualified detergent or the dosage
in the container is not correct.
* No salt in the softener
*Norinseagent
* Incorrect loading of dishes *
Something wrong with the drain pipe
in the home
* Flow and pressure of washing pump
* Detergent is not released from
dispenser
* Heating element is not working
* The nozzle is blocked by food
particles
*Nowatercomingintothe
dishwasher
*Thedispensermalfunctions
*Sthwrongwiththepressureswitch
and the charging water is not enough
The dishwasher couldn't
wash properly
* Wrong loading position of the dishes.
* Short circuit of startup capacitance
* Washing motor is blocked or burnt
*Pressureswitch
* Malfunction of the circuit board
The dishes are wet
* The customer chose the program
without drying performance
*Thermocouple doesn't work
properly
* Heating element is malfunctions
* Something is wrong with the
circuit board
The dishes are not completely dried
* Incorrect loading of the dishes
* Earlier opening of the door
* No rinse agent or the dosage is not
enough
* Incorrect selecting the program
* The passage of the breather is
blocked
* The drain pump does not drain out
water
* Detergent is not released from the
dispenser
* Noise from washing pump
* Noise from drain pump
* Noise from water inlet valve
*Noise from breather
Too much noise
* Incorrect loading of dishes
Feeling like to be electrically
shocked by the dishwasher
* The electrical wire in the house is
not earthed.
* Connection of the terminal box
* Grounding of the heating element
* Circuit and its components
Water leakage and flood of the
dishwasher
* Too much detergent
* Using the detergent with foam,
which is not the one intended for
using with dishwasher
6
*Pressureswitch
*Doorgasket
* Water leakage of pipes, gaskets
and bolts
*Drainhose
*Washingpump
* Softener valve
* Softener
*Breather
Dry-protection proof switch
just for hide heating element:
E3:heating error
E4:flooding error
Dry-protection proof switch is out
of work
*
*
*
* The work of the washing pump
is un-normal
* The filter is blocked
* Filling is not enough
* The micro switch connected with
the heating element is damaged.
*The pressure switch does not act
* Heating element or thermostat is
damaged or the wire is infirm.
* Press switch is damage or the hose
connected pressure switch is break
* The switch doesn't work
* The pressure switch is locked
* Please check the washing pump,
make sure it is ok.
* Clean the filter
*Replacethepressureswitch
assembly
* Please check the wire, make sure all
connection is firm
*Replacethethermostat
* Replace the hose and pressure switch
* Please replace the Dry protection
switch