1728 Orbit Way - Minden, Nevada 89423 P: 775-782-1700 F: 775-782-1701 info@maxtonvalve.com www.maxtonvalve.com
91
\\SERVER\CATALOG2019\2019CatalogRev2
Introduction
The Maxton Interlock Hydraulic Valve (ILV) is a solenoid operated, normally closed check valve
designed to prevent unintended elevator down movement. The ILV only allows the oil to flow in the
down direction when the solenoid coil is energized. Due to its unique design the up flow is
unrestricted and does not require power to the solenoid coil. The ILV should be installed adjacent to
the main control valve, no adjustments are required. A push button Manual Lowering is provided to
lower the hydraulic elevator in case of emergency.
The Maxton ILV complies with ASME A17.1 / CSA B44
Specifications
RATED FLOW Maximum 360 gpm (1362 l/min)
Operating Pressure
Minimum 100 psi (6.9 bar)
Maximum 800 psi (55 bar)
Line Connections
Jack Port (Flange) 2, 2½” NPT or Grooved
Tank Port (Flange) 2, 2½” NPT or Grooved
Operating Temperature 80°-150° F (26° - 65° C)
Oil Type Hyd. ISO VG 32
150 SUS @ 100° F (38° C)
Overall Dimensions
Width 11 1/4 inches (286mm) Height 8 13/16 inches (224mm)
Depth 5 1/4 inches (133mm) Weight 28 lbs. (12.7kg)
Standard Features
 Unit body construction.
 Steel sleeve inserts in valve body
 Grooved or threaded line connections
 115 VDC solenoid coil
 Factory tested prior to shipping
 2 year limited warranty
Optional Features
 3" Grooved flanges
 120 VAC / 12 VDC solenoid coil
 230 VAC solenoid coil
 115 VAC / 24 VDC solenoid coil
INTERLOCK HYDRAULIC VALVE (UNINTENDED MOVEMENT)