1
FT200 (48mm*48mm)
FT204 (48mm*96mm)
FT205 (96mm*48mm)
FT207 (72mm*72mm)
FT209 (96mm*96mm)
72
72
67.2 67.2
68.47
48 68.4
7
44.644.6
48
96
91.2
48
44.6
68.47
96
91.2
91 .2
96 68.47
FT200
1
2
7
17
18
1016
15
14
OP1
OP2
INP2
RS-485
A+
B
mA
V
TC
A
B
B-
+5V
AUX-
AUX+
AL1
AL2
85~265V
AC
L
N
13
12
11
9
8
6
5
4
3
FT207
B
B
mA
mA
V
V
TC
TC
A
A
B
B
FT204/FT209/FT205
TRS
OP1
OP2
RS-485
A+
B-
AL1
AL2
85~265V
AC
L
N
17
18
16
15
14
13
23
24
22
21
20
19
7
10
12
11
9
8
1
2
6
5
4
3
TRS
TRS
TRS
GND-
GND-
AUX-
AUX-
AUX+
AUX+
OP1
OP2
INP2+
INP2+
INP3+
RS-485
A+
B-
AL1
AL2
AU3
AU3
85~265V
AC
L
N
11
12
10
17
18
16
15
14
13
7
9
8
1
2
6
5
4
3
LCD display advanced digital temperature controller
User Manual
FT20X-800-C1
Please read this manual carefully and keep this manual for further reference
Features
0
Ambient temp 0-50 C, humidity 0-80%RH
Communication: RS-485, modbus-RTU, pattern 8-(N,O,E)-(1,2)
Special features: all parameters distributed in three levels, parameters can be manually
designate to different level
Add-on feature: auto/manual control, run/stop function, even SV input
Program version: PID mode, ramp up mode, temp constant mode, soft-start
Control mode: PID with auto-tuning, on/off, heating or cooling, heating+cooling, 3 wires
proportional valve control, valve control with feedback signal, output restrain
Alarm:AL1/AL2 relay output, excitation, non-excitation, delay output, alarm lock function
Alarm mode: PV, deviation, absolute, band, alarm standby, PV deviation alarm ramp
start-up alarm, ramp end alarm, Loop break alarm,heater break alarm
Output: relay, SSR drive, analog, triac,re-transmission
0.2% measuring accuracy, maximum resolution 0.1 for TC and RTD input
LCD three color VA display, bar graphic,output percentage MV1/MV2 or feedback MVFb display
1: Model number and ordering information
Please check this ordering information and specify the code when order with us
Model
Item number( Panel size: width x height)
2. Size and mounting
FT200
FT204
FT205
FT207
Unit:mm
Unit:mm
Unit:mm
FT209
Unit:mm
3. Wiring diagram
Main output Relay
250Vac 5A(resistive load)
Alarm relay
250Vac 3A(resistive load)
4-20mA output(maximum load
resistance 500 ohm)
12VDC pulse output( 20mA)
Remark
Above is a general wiring diagram, please
always refer to the connection diagram on
the side of the controller
INP2/INP3 used for remote SV, or position
feedback or remote output% under manual
mode,Please refer to wiring diagram on the
unit for single phase or three phase triac output
option
:Controller type
1
U
R Ramp and soak mode(with timer)
Standard PID type
R
V
D 4-20mA output
SSR Drive/Voltage pulse output
Relay output
E
0-10Vdc
F 0-20mA
:Power Source
5
96 85~265Vac 50/60HZ
:Number of Alarms
4
1
2
1 alarm
2 alarms
24 24Vac/24Vdc
:OUTPUT 1
2
5 0-5Vdc
7 1-5Vdc
T Traic single phase zero-crossing trigger
A Relay output, for motor valve direct act control
R
V
D 4-20mA output
SSR Drive/Voltage pulse output
Relay output
E
0-10Vdc
F 0-20mA
:OUTPUT 2(output 2 is only available for heating+cooling controller)
3
5 0-5Vdc
7 1-5Vdc
T Traic single phase zero-crossing trigger
A Relay output, for motor valve reverse act control
N No output2( For single output controller, choose code N)
3
3 alarms
X Motor valve direct/reverse control version(two relays)
:PV/SV re-transmission
6
N No re-transmission function
A 4-20mA re-transmission via OP2
B 0-20mA re-transmission via OP2
E 0-10Vdc re-transmission via OP2
F 4-20mA re-transmission via AU3
G 0-20mA re-transmission via AU3
K 0-10Vdc re-transmission via AU3
:RS-485 Communication
7
N No communication feature
K RS-485 modbus RTU communication
:AUX power source
8
N No aux power
A 24Vdc isolated
B 24Vdc grounded
C 12Vdc isolated
D 12Vdc grounded
:Position feedback(analong feedback input from INP2)
9
N No position feedback
C 0-5Vdc/potentiomter
A 4-20mA
D 1-5Vdc
B 0-20mA
E 0-10Vdc
:Remote SV setting
10
N No remote SV feature
C 0-5Vdc via INP2
A 4-20mA via INP2
D 1-5Vdc via INP2
B 0-20mA via INP2
E 0-10Vdc via INP2
F 4-20mA via INP3
G 0-20mA via INP3
H 0-5Vdc via INP2
J 1-5Vdc via INP3
K 0-10Vdc via INP3
W D1/D2 terminals event input
:Manual output% remote setting
11
N No remote SV feature
C 0-5Vdc via INP2
A 4-20mA via INP2 B 0-20mA via INP2
F 4-20mA via INP3
G 0-20mA via INP3
H 0-5Vdc via INP3
K 0-10Vdc via INP3
E 0-10Vdc via INP2
Vertical
Horizontal
FT20X-800-C1