Ventamatic, Ltd. P.O. Box 728, Mineral Wells, TX 76068-0728 1-800-433-1626 Fax: 940.325.9311 www.BVC.com
QTY Printed
SKU / Document #
©2020 VENTAMATIC, LTD. 2020 HVFF10 INS MANUAL 0420/#1149
2020 HVFF10 INS Manual #1149
HVFF10 Mini Turbo
Owner’s Manual
SAFETY
This safety alert symbol is used to alert you to potential
personal injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
Danger indicates an imminently hazardous situation, which,
if not avoided, will result in death or serious injury.
DANGER
Warning indicates a potentially hazardous situation, which,
if not avoided, could result in death or serious injury.
WARNING
Caution indicates a potentially hazardous situation, which,
if not avoided, may result in minor or moderate injury.
CAUTION
Used to indicate an electrical shock or electrocution hazard.
ELECTRICAL
SHOCK
SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
Question and Answer IconNeed help?

Do you have a question about the Maxx air HVFF10 Mini Turbo and is the answer not in the manual?

Summary

General Safety Information

DANGER Safety Alert

Indicates an imminently hazardous situation resulting in death or serious injury if not avoided.

WARNING Safety Alert

Indicates a potentially hazardous situation resulting in death or serious injury if not avoided.

CAUTION Safety Alert

Indicates a potentially hazardous situation resulting in minor or moderate injury if not avoided.

Electrical Shock Hazard

Indicates an electrical shock or electrocution hazard.

Assembly and Operating Instructions

Operating Precautions

Read and follow all instructions before operating. Do not use if any part is damaged or missing.

Safety Warnings During Operation

Do not expose to water/rain. Avoid solid state speed control devices. Ensure proper plug fitment.

Rules for Safe Operation

Do not insert objects into guard, disconnect when moving or cleaning, use on stable surface.

Base Assembly

Instructions for assembling the fan base using washers, base arm, and knob assembly.

Adjusting Fan Tilt

How to adjust the fan head tilt using the knob to loosen and tighten the tilt nut.

Speed Control and Overheat Protection

Explanation of speed settings (LOW, MEDIUM, HIGH) and the automatic thermal cutoff feature.

Installation and Maintenance

Wall Fan Installation Warning

Mount on wooden wall only. Ensure secure location. Recommended for qualified electricians.

Cleaning Instructions

Unplug before cleaning. Use soft damp cloth. Do not use harmful cleaning solutions or bend blades.

Parts Identification

List of fan components with corresponding part numbers and names for identification.

Ventamatic Limited Warranty

Warranty Coverage Period

Product warranted against defects for one (1) year from original retail purchase date.

Exclusions and Limitations

Excludes defects from abuse, faulty installation. No warranty for consequential damages.

Starting a Warranty Claim

Contact Ventamatic, Ltd. for RGA form. Retain sales slip as proof of purchase.

Overview

This document serves as the owner's manual for the MAXX AIR HVFF10 Mini Turbo fan, providing comprehensive instructions for its assembly, operation, safety, cleaning, and warranty information. The fan is designed for personal air circulation and can be used as a floor-standing unit or mounted on a wall.

Function Description

The MAXX AIR HVFF10 Mini Turbo is an air circulating fan designed to provide cooling and ventilation. It features a powerful motor and a fan blade assembly encased within a protective grille and metal drum. The fan operates with three distinct speed settings—LOW (1), MEDIUM (2), and HIGH (3)—allowing users to adjust the air velocity according to their comfort and environmental needs. The motor is designed to withstand continuous operation, and it incorporates a thermal cutoff safety feature that automatically shuts off the fan if it overheats, preventing potential damage or hazards. Once the fan has cooled down, it can be unplugged and then reconnected to resume operation.

The fan is equipped with an adjustable tilt mechanism, enabling users to direct the airflow precisely where it is needed. This feature enhances its versatility, making it suitable for various applications, from personal cooling to improving air circulation in a room. The fan also includes a convenient carry handle, facilitating easy transportation from one location to another. Its 3-prong plug ensures a secure and grounded electrical connection, contributing to safe operation.

Beyond its floor-standing configuration, the HVFF10 Mini Turbo can also be installed as a wall-mounted fan. This dual functionality allows for flexible placement, optimizing space and directing airflow from an elevated position. For wall installation, specific safety guidelines must be followed, including mounting on a wooden wall capable of supporting the fan's weight and ensuring the electrical connection is handled by a qualified electrician.

Usage Features

The MAXX AIR HVFF10 Mini Turbo is designed for user-friendly operation with several key features:

  • Adjustable Tilt: The fan head can be tilted to various angles to direct airflow. To adjust the tilt, the user loosens a knob by turning it counter-clockwise, positions the fan head to the desired angle, and then tightens the knob by turning it clockwise. This allows for precise targeting of airflow, whether for personal cooling or general room ventilation.
  • 3 Speed Operation: The fan offers three speed settings—LOW (1), MEDIUM (2), and HIGH (3)—controlled by a rotary switch. This allows users to select the appropriate air velocity for different situations, from a gentle breeze to a powerful airflow. The motor is designed for continuous operation, providing consistent performance.
  • Carry Handle: A built-in carry handle makes the fan easy to transport between rooms or to different locations within a space. This enhances the fan's portability and convenience.
  • Floor or Wall Mount: The fan can be used as a traditional floor-standing unit or mounted on a wall. For wall installation, the manual specifies mounting on a wooden wall and recommends professional installation by a qualified electrician to ensure safety and proper support. Hardware for wall mounting is not included.
  • Base Assembly: The assembly of the fan base is straightforward. It involves aligning a washer assembly with a pre-drilled hole on the fan housing, placing the base arm against the washer assembly, and then inserting and tightening a knob and tilt nut assembly through the base hole and into the washer. This process is repeated for the other side of the fan.
  • Safety Features: The fan incorporates several safety measures. It has a 3-prong grounded plug to reduce the risk of electrical shock. A thermal cutoff automatically shuts off the fan if the motor overheats, preventing damage and potential hazards. The manual also emphasizes rules for safe operation, such as never inserting fingers or objects through the grille and disconnecting the fan when moving it or performing maintenance.

Maintenance Features

Proper maintenance of the MAXX AIR HVFF10 Mini Turbo is essential for its longevity and safe operation. The manual provides clear instructions for cleaning and general care:

  • Cleaning: Before any cleaning, the fan must be unplugged from the electrical supply source to prevent electric shock. The cleaning process involves using a soft, damp cloth to wipe down the fan surfaces, followed by wiping with a dry cloth. Users are cautioned against using cleaning solutions that could harm the fan's paint or plastic components. It is also important not to bend the fan blades during cleaning to avoid damage.
  • Reinstallation of Safety Devices: After any servicing or cleaning that requires removal of components, all safety devices, including grilles and blades, must be reinstalled or remounted as they were originally. This ensures the fan maintains its protective features and operates safely.
  • Sealed Motor Bearings: The motor bearings of the fan are permanently sealed, meaning they do not require additional lubrication. This simplifies maintenance, as users do not need to worry about oiling or greasing the motor.
  • No User Serviceable Parts: The manual implies that the internal components, particularly the motor and electrical wiring, are not intended for user servicing beyond basic cleaning. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person, rather than by the end-user, to avoid hazards.
  • Regular Inspection: Although not explicitly stated as a "maintenance feature," the safety guidelines implicitly encourage regular inspection of the fan for any damaged or missing parts. The manual warns against using the fan if any part is damaged or missing, highlighting the importance of ensuring the fan is in good working condition before operation.
  • Secure Assembly: For safe operation, the manual specifically warns that the FRONT and REAR GUARD screws must be completely screwed down in a locked position. This ensures the protective grilles are securely in place, preventing access to moving parts during operation.

Overall, the MAXX AIR HVFF10 Mini Turbo is designed to be a reliable and versatile air circulation device, with user-friendly features and clear guidelines for safe and effective operation and maintenance.

Maxx air HVFF10 Mini Turbo Specifications

General IconGeneral
Power SourceElectric
Voltage120V
Power1500 Watts
Heating Settings2
ThermostatAdjustable
Safety FeaturesTip-Over Switch, Overheat Protection
ModelHVFF10 Mini Turbo