EasyManuals Logo

Maytag MLG31PCB User Manual

Maytag MLG31PCB
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
20
G. GAS INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the
gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of
such codes,
ALL plumbing connections, materials, and workmanship must conform to the applicable requirements
of the National Fuel Code ANSI Z223.1-LATEST EDITION or in Canada, CAN/CGA-B149.1-M91 (Natural
Gas) or CAN.CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation
and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual, can result in personal injury and improper operation of the dryer.
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted, could cause
irreparable damage to the gas valve, which will VOID THE WARRANTY.
WARNING: FIRE OR EXPLOSION COULD RESULT due to failure of isolating or
disconnecting the gas supply as noted.
1. Gas Supply
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI
Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances
and must be done by a qualified professional.
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and
can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated on the dryer data label. If this information
does not agree with the type of gas available, contact the dealer who sold the dryer or contact Maytag Co.
IMPORTANT: Any burner changes or conversions must be made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters) unless
elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was
placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet
(609.6 meters) is made by changing each burner orifice. If this conversion is necessary, contact the dealer
who sold the dryer or contact Maytag Co.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Maytag MLG31PCB and is the answer not in the manual?

Maytag MLG31PCB Specifications

General IconGeneral
BrandMaytag
ModelMLG31PCB
CategoryDryer
LanguageEnglish

Related product manuals