Part No. 113075 1 -12/21/98-100
Software revision.
Upper or lower thermistor counts are alternately displayed.
Upper and lower thermistor calibration counts are alternately displayed.
In help mode, the other display symbols and elements are mapped to reflect the state of various inputs and outputs
as follows:
PRICE - upper motor trying to run
ADD - upper pocket heating
BATTERY - upper motor sensed
OR - lower motor trying to run
SELECT - lower pocket heating
CYCLE - lower motor sensed