C
FCEOS Enterprise-specific Trap Definitions
C-51
McDATA Private Enterprise MIB
fcEosCTACounter
Syntax INTEGER
Access read-only
Status mandatory
Description This only applies when the alert type is a Counter Threshold Alert. It
specifies statistical counter or counter set to be monitored.
Sequence
::= { fcEosTAEntry 11 }
FCEOS Enterprise-specific Trap Definitions
fcEosPortScn
Enterprise mcData
Variables { fcEosPortOpStatus }
Description An fcEosPortScn(1) is generated whenever a Fc_Port changes its
operational state. For instance, the Fc_Port goes from on-line to
offline.
Sequence
::= 1
fcEosFruScn
Enterprise mcData
Variables { fcEosFruStatus }
Description An fcEosFruScn(2) is generated whenever a FRU status changes its
operational state.
Sequence
::= 2
fcEosPortBindingViolation
Enterprise mcData
Variables { fcEosPortAttachedWWN }
Description An fcEosPortBindingViolation(3) is generated whenever the switch
detects that a port binding violation occurs.