Do you have a question about the McQuay MMC100D and is the answer not in the manual?
| Brand | McQuay |
|---|---|
| Model | MMC100D |
| Category | Air Conditioner |
| Language | English |
Outdoor units have auto reset high/low pressure cut-outs and discharge thermostat.
Detailed specifications for cooling-only units operating at 50Hz with R22 refrigerant.
Detailed specifications for heatpump units operating at 50Hz with R22 refrigerant.
Detailed specifications for cooling-only units operating at 50Hz with R407C refrigerant.
Detailed specifications for cooling-only units at 220V/60Hz with R22 refrigerant.
Detailed specifications for cooling-only units at 460V/60Hz with R22 refrigerant.
Cooling capacity performance tables for R22, 50Hz units.
Allowable operating temperature ranges for cooling-only operation.
Allowable operating temperature ranges for heatpump operation (Heating and Cooling).
Wiring diagram for MDB 075D/MMC 075D units with specific controller.
Wiring diagram for MDB 100D/MMC 100D units with specific controller.
Wiring diagram for MDB 125D/MMC 125D units with specific controller.
Wiring diagram for MDB 150D/MMC 150D units with specific controller.
Wiring diagram for MDB 150D2/MMC 075D x 2 units with sequential controller.
Wiring diagram for MDB 200D2/MMC 100D x 2 units with sequential controller.
Wiring diagram for MDB 250D2/MMC 125D x 2 units with sequential controller.
Wiring diagram for MDB 300D2/MMC 150D x 2 units with sequential controller.
Wiring diagram for MDB 400D4/MMC 100D x 4 units with sequential controller.
Wiring diagram for MDB 500D4/MMC 125D x 4 units with sequential controller.
Heatpump wiring diagram for MDB 075DR/MMC 075DR units with specific controller.
Heatpump wiring diagram for MDB 100DR/MMC 100DR units with specific controller.
Heatpump wiring diagram for MDB 125DR/MMC 125DR units with specific controller.
Heatpump wiring diagram for MDB 150DR/MMC 150DR units with specific controller.
Heatpump wiring diagram for MDB 150DR2/MMC 075DR x 2 units with sequential controller.
Heatpump wiring diagram for MDB 200DR2/MMC 100DR x 2 units with sequential controller.
Heatpump wiring diagram for MDB 250DR2/MMC 125DR x 2 units with sequential controller.
Heatpump wiring diagram for MDB 300DR2/MMC 150D x 2 units with sequential controller.
Heatpump wiring diagram for MDB 400DR4/MMC 100DR x 4 units with sequential controller.
Heatpump wiring diagram for MDB 500DR4/MMC 125DR x 4 units with sequential controller.
Refrigerant circuit diagram for MMC 075D/100D/125D/150D outdoor units.
Refrigerant circuit diagram for MLC 061C outdoor units.
Refrigerant circuit diagram for MMC DR series (R22) and M4MC DR series (R407C).
Precautions for scroll compressors, volumetric efficiency, vacuum, lubrication, and temperature damage.
Refer to local electrical codes for wiring diameter and ensure compliance.
Troubleshooting flowchart for scenarios where the unit does not cool.
Troubleshooting flowchart for insufficient cooling issues.
Troubleshooting flowchart for issues related to high discharge pressure.
Troubleshooting flowchart for issues related to low discharge pressure.
Troubleshooting flowchart for issues related to high suction pressure.
Troubleshooting flowchart for issues related to low suction pressure.
Troubleshooting flowchart for identifying and resolving noisy operation.