EasyManuals Logo

McQuay MWH Service Guide Book

McQuay MWH
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
50
Seven Segment Display
Model Board Handset
WMX 10 – 25G/GR VA3.0 SLM3
CKX 20 – 25A/AR VA3.0 SLM3
CKX 10 – 20C/CR VA3.0 SLM3
CEX 15 – 25E/ER VA3.0 SLM3
CCX 10 – 25C/CR VA3.0 SLM3
Cooling / Heat pump Model
Seven Segments Faulty Indication
E1 blinking Indoor temperature sensor loose / short
E2 blinking Outdoor temperature sensor loose / short
E3 blinking Communication error
E4 blinking Compressor overload protection
E5 blinking Pump fault
E6 blinking Compressor overheat / gas leak
E7 blinking IPM / PFC / Partial switching
E8 blinking Outdoor over current
E9 blinking Indoor fan feedback error

Other manuals for McQuay MWH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the McQuay MWH and is the answer not in the manual?

McQuay MWH Specifications

General IconGeneral
BrandMcQuay
ModelMWH
CategoryAir Conditioner
LanguageEnglish

Related product manuals