McQuay WHR Series Specifications

General IconGeneral
BrandMcQuay
ModelWHR Series
CategoryChiller
LanguageEnglish

Summary

Introduction

General Description

Overview of McQuay WHR SEASONPAK water chillers with MicroTech control.

Nomenclature

Explains the model designation system for WHR units.

Inspection

Guidance on checking equipment upon receipt for damage and correct model.

Installation

Handling

Precautions and methods for safely moving and handling the chiller unit.

Moving The Unit

Detailed instructions for moving the unit using skids, dollies, or hoisting.

Location

Specifies ideal indoor installation locations and ambient temperature requirements.

Space Requirements for Connections and Servicing

Details required clearances for piping and servicing around the unit.

Placing the Unit

Guidance on unit placement, floor considerations, and shipping bolts.

Vibration Isolators

Information on selecting and installing vibration isolators for the unit and piping.

Water Piping

General

General guidelines for water piping installation, codes, and support.

Chilled Water Piping

Specific requirements for chilled water piping, including flow direction and insulation.

Chilled Water Sensor

Describes the factory-installed chilled water sensor and its importance.

Flow Switch

Explains the necessity and installation of a water flow switch for unit protection.

Glycol Solutions

Water Pressure Drop

Evaporator water pressure drop

Graph for determining evaporator water pressure drop based on flow rate.

Condenser water pressure drop

Graph for determining condenser water pressure drop based on flow rate.

Condenser Water Piping

General

General guidelines for condenser water piping installation and considerations.

Head Pressure Control, Tower System

Methods for controlling head pressure in cooling tower systems.

Head Pressure Control, Well Water System

Recommended control for head pressure when using well water.

Single Condenser Heat Recovery - Arrangement W

Dual Condenser Heat Recovery - Arrangement H

Refrigerant Piping

Unit With Remote Condenser - Arrangement A

Guidance on refrigerant piping for units with remote air-cooled condensers.

Unit With Factory Mounted Condenser(s)

Information on units with factory-mounted condensers and potential issues.

Relief Valve Piping

Requirements for installing relief valve piping according to standards.

Refrigerant Piping

General guidelines for refrigerant piping installation and considerations.

Dimensional Data

Arrangement W (With Water Cooled Condensers) - WHR-120 DW thru 200 DW

Dimensional data and specifications for WHR-120DW to 200DW Arrangement W units.

Arrangement W (With Water Cooled Condensers) - WHR-210 DW thru 240 DW

Dimensional data and specifications for WHR-210DW to 240DW Arrangement W units.

Arrangement A (Without Water Cooled Condensers) - WHR-040 DA thru 110 DA

Dimensional data for WHR-040DA to 110DA Arrangement A units.

Arrangement A (Without Water Cooled Condensers) - WHR-120 DA thru 200 DA

Dimensional data for WHR-120DA to 200DA Arrangement A units.

Arrangement A (Without Water Cooled Condensers) - WHR-210 DA thru 240 DA

Dimensional data for WHR-210DA to 240DA Arrangement A units.

Arrangement H (With Heat Recovery Condensers) - WHR-040 DH thru 110 DH

Dimensional data for WHR-040DH to 110DH Arrangement H units.

Arrangement H (With Heat Recovery Condensers) - WHR-120 DH thru 200 DH

Dimensional data for WHR-120DH to 200DH Arrangement H units.

Arrangement H (With Heat Recovery Condensers) - WHR-210 DH thru 240 DH

Dimensional data for WHR-210DH to 240DH Arrangement H units.

Physical Data

WHR Unit Size 040 thru 110 D

Physical specifications for WHR units 040D through 110D.

WHR Unit Size 120 D thru 170 D

Physical specifications for WHR units 120D through 170D.

WHR Unit Size 175 D thru 240 D

Physical specifications for WHR units 175D through 240D.

Compressor Locations

Major Components

Electrical Data

Compressor motor amp draw

Table detailing compressor motor amp draw for various unit sizes and voltages.

Compressor motor amp draw (Continued)

Continuation of compressor motor amp draw data for larger unit sizes.

Wire sizing amps

Table providing wire sizing ampacity for different unit configurations and power supplies.

Wire sizing amps (Continued)

Continuation of wire sizing ampacity data for larger unit sizes.

Control Center

Wiring

Field Wiring, Power

Guidelines for field power wiring, including options and compliance with codes.

Typical Control and Safety Wiring Diagrams

Reference to diagrams for control and safety wiring.

Current Transformer

Explanation of the current transformer's function and wiring.

Electrical Legend

Explains the designations used in electrical schematics and diagrams.

Typical Power Wiring Diagrams

WHR 040 D THRU 080 D SINGLE POINT 208230 V AL, PW

Power wiring diagram for specific units and configurations.

WHR 040 D THRU 080 D SINGLE POINT 380415460575 V AL, PW

Power wiring diagram for specific units and voltages.

WHR 090 D THRU 110 D SINGLE POINT 208230380415575 V AL, PW

Power wiring diagram for specific units and voltages.

WHR 120 D THRU 175 D SINGLE POINT 208230 V AL, PW

Single point power wiring diagram for specific units and voltages.

WHR 180 D THRU 200 D SINGLE POINT 208230 V AL, PW

Single point power wiring diagram for specific units and voltages.

WHR 210 D THRU 240 D SINGLE POINT 208230380415460575 V AL, PW

Single point power wiring diagram for specific units and voltages.

Drawing Reference Decision Table for Compressor Power Schematics

Startup and Shutdown

Pre Startup

Detailed checklist for pre-startup checks and preparations before operating the chiller.

Startup

Steps for initiating operation of the chiller after pre-startup checks are complete.

Temporary Shutdown

Procedure for temporarily shutting down the chiller and its associated pumps.

Startup After Temporary Shutdown

Steps to restart the chiller after a temporary shutdown period.

Extended Shutdown

Procedure for safely shutting down the chiller for extended periods.

Startup After Extended Shutdown

Steps for restarting the chiller after an extended shutdown.

System Maintenance

General

General guidelines and best practices for maintaining the chiller unit.

Control Center

Guidance on servicing the electrical control center and safety precautions.

Electrical Terminals

Precautions for electrical terminals and maintenance.

Operating Limits

Specifications for normal operating limits of the chiller.

Compressor Oil Level

Procedures for checking and maintaining compressor oil levels.

Oil Equalization

Explanation of oil equalization lines and their function.

Refrigerant Sightglass and Moisture Indicator

How to interpret and maintain the refrigerant sightglass and indicator.

Crankcase Heaters

Information on crankcase heaters and their importance for startup.

System Service

Filter-Driers

Procedure for changing filter-driers in the refrigerant circuit.

Liquid Line Solenoid Valve

Information on the liquid line solenoid valve and its maintenance.

Thermostatic Expansion Valve

Details on the thermostatic expansion valve, its function, and adjustment.

Evaporator

Description of the evaporator and procedures for tube replacement.

Water Cooled Condenser

Description of the water-cooled condenser and its features.

Hot Gas Bypass (Optional)

Explanation of the hot gas bypass option and its operation.

In-Warranty Return Material Procedure

Compressor

Procedure for returning defective compressors under warranty.

Components Other Than Compressors

Procedure for returning other defective parts under warranty.

Troubleshooting Chart

Product Warranty