ATTENTION: If the heater stops due to
the intervention of the room thermostat
(optional article), the appliance will
switch back on automatically when
the temperature drops below the
threshold set.

REGULATION
Depending on the type of heater, the
appliance heat capacity can be regulated.
The heat capacity can be regulated by
acting on the knob positioned on the base
of the heater (Pic. 22) or on the pressure
regulator installed on the gas cylinder
(Pic. 23), depending on the model.
9. SWITCH-OFF FOR MANUAL
MODELS (... / ...M / ...DV / ...M DV)
9.1.Close the gas cylinder (Pic. 24).
9.2.Leave the fan to cool for about 60 s,
in order to prevent internal damage due
to overheating (heater internal cooling).
9.3.Take the “O/I” switch to position “O”
(Pic. 25).
9.4.Disconnect the heater from the
mains electricity (Pic. 26).
9.5.Disconnect the heater from the gas
supply pipe (Pic. 27-28-29).
10. SWITCH-OFF FOR
ELECTRONIC MODELS (...E /
...ET)
10.1.Take the “O/I” switch to position
“O” (Pic. 25). The ame goes out and
the heater performs the post-ventilation
phase. Wait for the cycle to be completed
in order to prevent internal damage due
to overheating (the phase is automatic
and can last 50 s÷5 min depending on
the internal/external temperature at the
heater).
►10.2.Close the gas cylinder (Pic. 24).
►10.3.Disconnect the heater from the
mains electricity (Pic. 26).
►10.4.Disconnect the heater from the
gas supply pipe (Pic. 27-28-29).
N.B.: Do not disconnect the heater
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.

MAINTENANCE
Have the after-sales assistance check
correct functioning of the heater at least
once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
►11.1.Before starting any type of
maintenance, care and repairs of the
appliance, carry out the switch-off
sequence [Par. 9. “SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV /
...M DV) or 10. SWITCH-OFF FOR
ELECTRONIC MODELS (...E / ...ET)”].
►11.2.Cleaning only concerns the air
vent (rear side) of the heater.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.

CONNECTION (...E / ...ET)
(optional)
Remove the plug connected to the
appliance and connect the room
thermostat (optional) (Pic. 30).
See wiring diagram (...E / ...ET).