6.0 CERTIFICATION/APPROVALS
Exd IIB version:
Certified to EN50014:1997, EN50018:2000 & EN50281-1-1:1998
EEx d unit (ATEX certification No. Baseefa 03ATEX0447)
EEx d IIB+H2 T85°C (Tamb -20°C to +55°C
Exd IIC version:
Certified to EN 60079-0, EN 60079-1, EN 61241-0 and EN 61241-1
Ex d unit (ATEX certification No. Baseefa08ATEX0320)
Ex d IIC Ex tD A21 T85°C (Tamb -20°C to +55°C) IP6X
Ex d IIC Ex tD A21 T135°C (Tamb -20°C to +90°C) IP6X
II 2 GD
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
D Signifies suitability for use in the presence of dust
Exem version:
Certified to EN50014, EN50019 & EN50028
EEx em unit (ATEX certification No. Baseefa03ATEX0428)
EEx em II T6 (-20°C to +55°C)
EEx em II T4 (-20°C to +55°C) (With resistors fitted)
The EEx em ATEX certificate and product label carry the ATEX group and category marking:
II 2 G
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
Or
EEx d IIB+H2 T200°C (Tamb -20°C to +125°C
Or
The Exd ATEX certificate and product label carry the ATEX group and category marking:
For Type HD1 Addressable Heat Detector Units which do contain an addressable module the marking remains as:
Ex d IIC Ex tD A21 T85°C (Tamb -20°C to +55°C) IP6X
)
)*
*Please refer to certification label for temperature rating