Ex ia version:
ATEX:
Certified to EN60079-0 & EN60079-11
Ex ia unit (ATEX certification No. Baseefa03ATEX0427)
Ex ia IIC T6 Ga (-55°C to +55°C) - HD1I version
Ex ia IIC T4 Ga (-55°C to +55°C) - HD1IR version
The Ex ia ATEX certificate and product label carry the ATEX group and category marking:
II 1 G
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
1 Signifies suitability for use in a zone 0 area
G Signifies suitability for use in the presence of gases
IECEx:
Certified to IEC60079-0 & IEC60079-11
Ex ia unit (IEC certification No. IECEx BAS 13.0010)
Ex ia IIC T6 Ga (-55°C to +55°C) - HD1I version
Ex ia IIC T4 Ga (-55°C to +55°C) - HD1IR version
The IECEx certificate and product label carry the IECEx equipment protection level marking
Ga
Where Ga signifies suitability for use in a Zone 0 surface industries area in the presence of gas.