Medonic CA530 - User Manual

Default Icon
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User´s Manual
Medonic CA620 + MPA + AD
Medonic CA620 + MPA
Medonic CA620
Medonic CA530 + MPA + AD
Medonic CA530 + MPA
Medonic CA530
Medonic CA620-CellGuard + MPA + AD
Medonic CA620-CellGuard + MPA

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Medonic CA530 and is the answer not in the manual?

Summary

Safety Instruction

Intended Use

Defines the product's purpose and requirements for proper use.

Counter Indications

Lists conditions or environments where the instrument should not be used.

Warranty Limitations

Outlines restrictions and conditions that may affect the instrument's warranty.

General Warnings

Covers electrical, biohazard, and contamination hazards associated with the instrument.

Emergency Procedure

Provides steps to follow in case of an instrument malfunction or emergency.

Installation

Unpacking the Instrument

Procedures for unpacking the instrument and checking contents.

Working Conditions

Requirements for the instrument's operating environment and mains supply.

Mechanical Check and Set-Up

Steps for physical installation, mechanical checks, and component setup.

Front Panel and Command Keys

Description of the instrument's front panel controls and keys.

Filling the system with reagents

Instructions for filling the instrument with the necessary reagents.

Initial System Configuration

CA620-CellGuard

Default configuration and mode selection for CA620-CellGuard.

Setting up the CA620-CellGuard for Pre-Donor Screening

Configuration steps for using the CA620-CellGuard in pre-donor screening mode.

Setting up the CA620-CellGuard for PLT Concentrate

Configuration steps for monitoring PLT concentrates with CA620-CellGuard.

CA620;530

Default configuration settings for CA620 and CA530 models.

Setting Date and Time

Procedure for configuring the instrument's date, time, and date format.

Printer Configuration

Steps to set up the connected printer and define print formats.

Routine Operation

Background Check

Procedure to perform a background check before sample analysis.

Analysing the Sample (Open Tube)

Steps for analyzing whole blood samples using the open tube inlet.

Analyzing the Sample (Pre-Dilute)

Procedure for analyzing pre-diluted blood samples.

Analysing the Sample (Micro Pipette Adapter, MPA)

Instructions for using the Micro Pipette Adapter with capillary samples.

Analysing the Sample (Cap Piercing Device)

Steps for using the optional cap piercing device for closed tubes.

Advanced User Options (CA620-CellGuard)

Switching between Blood and PLT concentrate modes on CA620-CellGuard.

User Interface

Sample Memory

How to access, view, and manage stored sample data and statistics.

Setup Menu

Overview of instrument settings, calibration, and normal range definitions.

Setup Menu 2

Access to less common settings like Machine ID, blood detector, and units.

Calibration and controls

Calibration on a Known Sample

Procedure for calibrating using a reference sample with known values.

Calibration Through a Certified Calibrator

Steps for calibrating the instrument using a certified calibrator.

QC and Blood Controls

Introduction

Overview of Quality Control (QC) memory, X-B algorithm, and Levey-Jennings plots.

Maintenance, Shut-Down & Transport

Trouble Shooting

Counting Time HI (TU & TL)

Troubleshooting issues related to high or low counting times (TU/TL).

Counting Time LO

Troubleshooting air in the metering unit indicated by 'LO' counting time.

HGB Value Flagged with LO

Diagnosing low blank reference voltage flagged as 'LO' for HGB.

HGB Value Flagged with HI

Diagnosing out-of-range blank reference voltage flagged as 'HI' for HGB.

HGB Value Flagged with OF

Troubleshooting photometer offset voltage errors flagged as 'OF'.

Summary

Safety Instruction

Intended Use

Defines the product's purpose and requirements for proper use.

Counter Indications

Lists conditions or environments where the instrument should not be used.

Warranty Limitations

Outlines restrictions and conditions that may affect the instrument's warranty.

General Warnings

Covers electrical, biohazard, and contamination hazards associated with the instrument.

Emergency Procedure

Provides steps to follow in case of an instrument malfunction or emergency.

Installation

Unpacking the Instrument

Procedures for unpacking the instrument and checking contents.

Working Conditions

Requirements for the instrument's operating environment and mains supply.

Mechanical Check and Set-Up

Steps for physical installation, mechanical checks, and component setup.

Front Panel and Command Keys

Description of the instrument's front panel controls and keys.

Filling the system with reagents

Instructions for filling the instrument with the necessary reagents.

Initial System Configuration

CA620-CellGuard

Default configuration and mode selection for CA620-CellGuard.

Setting up the CA620-CellGuard for Pre-Donor Screening

Configuration steps for using the CA620-CellGuard in pre-donor screening mode.

Setting up the CA620-CellGuard for PLT Concentrate

Configuration steps for monitoring PLT concentrates with CA620-CellGuard.

CA620;530

Default configuration settings for CA620 and CA530 models.

Setting Date and Time

Procedure for configuring the instrument's date, time, and date format.

Printer Configuration

Steps to set up the connected printer and define print formats.

Routine Operation

Background Check

Procedure to perform a background check before sample analysis.

Analysing the Sample (Open Tube)

Steps for analyzing whole blood samples using the open tube inlet.

Analyzing the Sample (Pre-Dilute)

Procedure for analyzing pre-diluted blood samples.

Analysing the Sample (Micro Pipette Adapter, MPA)

Instructions for using the Micro Pipette Adapter with capillary samples.

Analysing the Sample (Cap Piercing Device)

Steps for using the optional cap piercing device for closed tubes.

Advanced User Options (CA620-CellGuard)

Switching between Blood and PLT concentrate modes on CA620-CellGuard.

User Interface

Sample Memory

How to access, view, and manage stored sample data and statistics.

Setup Menu

Overview of instrument settings, calibration, and normal range definitions.

Setup Menu 2

Access to less common settings like Machine ID, blood detector, and units.

Calibration and controls

Calibration on a Known Sample

Procedure for calibrating using a reference sample with known values.

Calibration Through a Certified Calibrator

Steps for calibrating the instrument using a certified calibrator.

QC and Blood Controls

Introduction

Overview of Quality Control (QC) memory, X-B algorithm, and Levey-Jennings plots.

Maintenance, Shut-Down & Transport

Trouble Shooting

Counting Time HI (TU & TL)

Troubleshooting issues related to high or low counting times (TU/TL).

Counting Time LO

Troubleshooting air in the metering unit indicated by 'LO' counting time.

HGB Value Flagged with LO

Diagnosing low blank reference voltage flagged as 'LO' for HGB.

HGB Value Flagged with HI

Diagnosing out-of-range blank reference voltage flagged as 'HI' for HGB.

HGB Value Flagged with OF

Troubleshooting photometer offset voltage errors flagged as 'OF'.

Medonic CA530 Specifications

General IconGeneral
BrandMedonic
ModelCA530
CategoryLaboratory Equipment
LanguageEnglish