EasyManuals Logo
Home>Megmeet>Thermostat>MTC-08-NT

Megmeet MTC-08-NT User Manual

Default Icon
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
BFM
Content
Remarks
Nat
ure
Sa
ve
CH1/CH5
CH2/CH6
CH3/CH7
CH4/CH8
M8/M12
M9/M13
M10/M14
M11/M15
Auto-tuning setting
of CH1- CH8 *7
Default value0
0:Not self-tuning or aut
o-tuning has been
completed
1Auto-Tune
R/W
Y
#1000/#10
04
#1001/#10
05
#1002/#10
06
#1003/#10
07
Control mode
setting
Default value2
0Hand 1ON/OFF
3:PID
R/W
Y
#1008/#10
12
#1009/#10
13
#1010/#10
14
#1011/#10
15
Heat/cool action*8
Default value1
0:Cooling
1:Heating
2:Heating and cooling
(air cooling)
3:Heating and cooling
(water cooling)
4:Position ratio PID
R/W
Y
#1016/#10
20
#1017/#10
21
#1018/#10
22
#1019/#10
23
Manual output of set
value
Default value0
Range0.0100.0(%)
R/W
Y
#1024/#10
28
#1025/#10
29
#1026/#10
30
#1027/#10
31
Adjust sensitivity
SettingON/OFF
control method is
effective
Default value:100
Unit0.1/
Range0~999
R/W
Y
BFM
Content
Remarks
Nat
ure
Sa
ve
CH1/CH5
CH2/CH6
CH3/CH7
CH4/CH8
#1032/#10
36
#1033/#10
37
#1034/#10
38
#1035/#10
39
Auto-tuning
deviation setting
Default value0
Unit0.1/
Range:±input range
R/W
Y
#1101/#11
05
#1102/#11
06
#1103/#11
07
#1104/#11
08
Heat side
proportional band
adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1109/#11
13
#1110/#11
14
#1111/#11
15
#1112/#11
16
Heat side integral
time adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1117/#11
21
#1118/#11
22
#1119/#11
23
#1120/#12
4
Heat side derivative
time adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1125/#11
29
#1126/#11
30
#1127/#11
31
#1128/#11
32
Cool side
proportional band
adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1133/#11
37
#1134/#11
38
#1135/#11
39
#1136/#11
40
Cool side integral
time adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1141/#11
45
#1142/#11
46
#1143/#11
47
#1144/#11
48
Cool side derivative
time adjusting factor
Default value100%
Setting range:0~1000%
R/W
Y
#1149/#11
53
#1150/#11
54
#1151/#11
55
#1152/#11
56
Set change rate
limit rise * 10
Default value0
Range:0~range,
Unit:℃/second
R/W
Y
#1157/#11
61
#11581162
#1159/#11
63
#1160/#11
64
Set change rate
limit drop * 10
Default value0
Range:0~range,
Unit:℃/second
R/W
Y

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megmeet MTC-08-NT and is the answer not in the manual?

Megmeet MTC-08-NT Specifications

General IconGeneral
BrandMegmeet
ModelMTC-08-NT
CategoryThermostat
LanguageEnglish