QUICK START GUIDE: MICRON PUMP SERIES
Warning: Risk of electrical shock. Carelessness may produce injury or death.
Warning: Hot zone with high temperatures. Risk of burns. Use thermal
protective equipment.
Warning: System under pressure. Risk of burns or particle projection. Use
thermal protective equipment and googles.
Warning: Important information for the correct use of the system. May include
one or several of the previous hazards, and therefore must be kept in mind to
avoid damage and injury.
Components and accessories Dimensions/Free space
Mounting the equipment Electrical power connection
Electrical power connection
Warning: The melters/applicators are equipment with current technology and with certain
foreseeable risks. Therefore, only allow qualified personnel with sufficient training and experience
to use, install or repair this equipment.
In case of doubts in the moment of installation, refer to the corresponding instructions manual.
ITEM DESCRIPTION DIMENSIONS
A EQUIPMENT LENGTH 5L 588 mm
10L 671 mm
20L 671 mm
35L 742 mm
B EQUIPMENT WIDTH 5L 339 mm
10L 339 mm
20L 383 mm
35L 435 mm
C EQUIPMENT HEIGHT 5L 481 mm
10L 481 mm
20L 526 mm
35L 673 mm
D EQUIPMENT HEIGHT WITH LID OPEN 5L 628 mm
10L 760 mm
20L 875 mm
35L 1067 mm
R
S
T
N
T N PE F1 F2 F3 N PE
230V 1~ 50 Hz + N + PE
400V 3~ 50 Hz + N + PE
230V 1~ 50 Hz + N + PE
400V 3~ 50 Hz + N + PE
MICRON 20, 35
MODEL No. OUTPUT 1 FHASE 3 FHASES
230 VAC Δ 400 VAC Y
micron 5 2 20.87 A 13.73 A 10.00 A
4 31.30 A 18.45 A 10.87 A
6 41.74 A 27.49 A 16.09 A
micron 10 2 25.22 A 17.86 A 14.35 A
4 35.65 A 21.91 A 14.35 A
6 46.09 A 27.49 A 16.09 A
micron 20 2 27.39 A 19.96 A 16.52 A
4 37.83 A 23.89 A 16.52 A
6 48.26 A 28.24 A 16.52 A
micron 35 2 33.91 A 24.55 A 16.09 A
4 44.35 A 29.35 A 21.30 A
6 54.78 A 37.27 A 26.52 A
Meler Gluing Solutions, S.A
P.I. Los Agustinos, calle G, nave D-43
E - 31160 ORCOYEN Navarra (España)
Tel.: + 34 948 351 110
Fax: + 34 948 351 130
e-mail: info@meler.es
www.meler.eu
GLUING SOLUTIONS
3
1
R
S
T
N
2
Ø6-12mm
M8
M8
MICRON 5, 10, 20
M8
M8
Fitting straight short
Warning light
VP system
Low level
detector
Automatic
feeder
Adaptation plate
Hose

Other manuals for Meler Micron 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meler Micron 5 and is the answer not in the manual?

Meler Micron 5 Specifications

General IconGeneral
BrandMeler
ModelMicron 5
CategoryWater Pump
LanguageEnglish

Related product manuals