Make sure that the hose line:
-Is not crushed or kinked.
-Is a safe distance from the burner.
-Open the valve on the gas bottle.
Never check for leaks with an open
or near sources of ignition.
Check all connections with a leakage test spray. If there are no bubbles forming on the test, there
are no leaks.
Gas Valve Assembly:
This assembly consists of an adjusting devise with an incorporated safety pilot, a burner with an electric
lighter. The adjusting devise can be set to 3
positions.
Max: Maximum cooling
Min: Minimum cooling
Ignition position/burner gas supply closed
Ensure that:
The thermostat control dial for 220-240V operation is in the minimum position.
The battery plug is not connected.
Press the ignition switch and hold it down for approx. 10 seconds to force out any air in the hose
connection.
START UP:
Step 1.
Open the valve of the gas cylinder
Step 2.
Press and hold the adjusting knob at the same time, then turn the knob anti-clockwise to Max.
Step 3.
NOTE: If the appliance has not been ignited for a long period, or if the gas cylinder has been changed,
there may be some air in the duct, so it may fail to ignite.
If the appliance fails to ignite, try it again after approximately 10 seconds.
TO DISCONNECT FROM THE GAS SUPPLY:
Shut
the gas cylinder or the pressure regulator.
Turn the knob to the OFF position.