CHARGING & STARTING SYSTEM
Page 2B-26 90-855347R1 JANUARY 1999
Starter Circuit Troubleshooting Flow Chart
Starter Motor Does Not Turn
SAFETY WARNING: Disconnect yellow (starter motor)
cable from starter solenoid test point 1 BEFORE making
tests 1–thru–7 to prevent unexpected engine cranking.
TEST 1
Use an ohmmeter (Rx1 scale) and connect meter leads
between NEGATIVE (–) battery post and common power-
head ground.
No Continuity Indicated – There is an open circuit in the
BLACK NEGATIVE (–) battery cable between the NEGATIVE (–)
battery post and the powerhead.
Check cable for loose or corroded connections.
Check cable for open.
Continuity Indicated
Proceed to TEST 2
Test 2
a. Disconnect BLACK ground wire(s) from Test Point 2.
b. Connect voltmeter between common engine ground and Test Point 2.
c. Turn ignition key to “Start” position.
No voltage reading:
proceed to TEST 3.
TEST 3
a. Reconnect BLACK ground wire.
b. Connect voltmeter between common engine ground and Test Point 3.
c. Turn ignition key to “Start” position.
12 Volt Reading*
Check BLACK ground wire for poor connection
or open circuit.
Reconnect ground wire to starter solenoid.
Proceed to TEST 7.
12 Volt Reading
Defective starter solenoid
TEST 4
a. Connect voltmeter between common
engine ground and Test Point 4.
b. Turn ignition key to “Start” position.
12 Volt Reading*
Neutral start switch is open or YELLOW/RED
wire is open between Test Points 4 and 3.
TEST 5
Connect voltmeter between common
engine ground and Test Point 5
12 Volt Reading*
Defective ignition switch.
TEST 6
Check for voltage between common engine ground and Test Point 6.
No voltage reading:
Check RED wire between battery(+)
POSITIVE terminal and Test Point 6.
12 Volt Reading*
Check fuse in RED wire between Test
Points 5 and 6.
Check for open RED wire between Test
Points 5 and 6.
*Battery Voltage
No voltage reading:
proceed to Step 4
No voltage reading:
proceed to Test 5
No voltage reading:
proceed to Test 6