17
EN ENGLISH
After Usage
Care and maintenance
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
Unless otherwise specied, we recommend that an expert carries out an external
test every 2 years and an internal test every 5 years as well as a strength test every
10 years.
Observe the instructions in the section entitled “Safety”.
Never leave liquid in the device.
Collect and dispose of the residual liquid and the tank according to all applicable
laws, requirements and regulations.
Follow the instructions of the spray product manufacturer!
Clean the protective equipment and yourself every time after usage.
Observe the instructions in the section entitled “Safety”.
5. Wipe o the device with a moist cloth.
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry place
protected from sunlight and freezing temperatures (Fig. 16).
1. Pull up the red piston pressure gauge [16] until the tank is depressurized. (Fig. 5)
2. Lock the piston rod with handle [13]. (Fig. 6)
3. Unscrew the pump [2] from the tank. (Fig. 7)
4. Dilute the remaining quantity twice in a row with ½ liter of water each time and spray the
resulting liquid onto the treated area.
After using the device 50 times or at least once a year:
• Unscrew the pump [2] from the tank. (Fig. 7)
• Dismantle the pump [2]. (Fig. 17)
• Grease the O-ring [19] and the sleeve [20]. (Fig. 18)
• Assemble the pump.
• Lock the piston rod with handle [13] and screw the pump [2] into the tank [1].
• Clean the nozzle [21] under running water. (Fig. 22)
• Unscrew the handgrip [41] from the shut-o valve [9].
• Remove the lter [22] and clean it under running water. (Fig. 24)
• Disassemble the shut-o valve [9]. (Fig. 28)
a) Loosen the four screws and pull the half shells [42] apart.
b) Screw the sealing cap [45] from the valve body [44] and pull the pressure bolt [25]
from the valve body [44]. (Fig. 29)
• Grease the O-rings [24]. (Fig. 29)
• Assemble the shut-o valve [9].
• Take the hose [4] with the discharge lter [34] out of the tank and clean the discharge
lter under running water. (Fig. 24)
6993140_0223_CLEANER_PROFIPLUS_15Spr.indd 17 14.02.2023 15:17:03