WARNING
Improper and unsafe use of this compressor can result in death or serious bodily injury!
This manual contains important information about product safety.
Please read and understand this manual before operating the compressor.
Please keep this manual available for others before they use the compressor.
AVERTISSEMENT
Une utilisation du compresseur de manière incorrecte ou ne respectant pas les
consignes de sécurité peut entraîner la mort ou de graves blessures!
Ce manuel renferme des informations importantes relatives à la sécurité.
Veuillez lire attentivement toutes les instructions avant de mettre le compresseur en
service.
Laissez ce manuel à la disposition des personnes qui vont utiliser le compresseur.
ADVERTENCIA
¡La utilización inadecuada e insegura de este compresor puede resultar en la muerte
o en lesiones serias!
Este manual contiene información importante sobre la seguridad del producto.
Antes de utilizar el compresor, lea y entienda bien este manual.
Guarde este manual as mano para que otras personas puedan leerlo antes de utilizar
el compresor.
INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR
MANUEL D’UTILISATION ET CONSIGNES DE SÉCURITÉ DU COMPRESSEUR
MANUAL DE INSTRUCCIONES Y INSTRUCCIONES DE SEGURIDAD PARA EL COMPRESOR DE AIRE
MODEL
MODÈLE
MODELO
EC 914S
00BookEC914SNA.indb100BookEC914SNA.indb1 2020/06/0813:46:322020/06/0813:46:32

Table of Contents

Questions and Answers

  • A
    Alyssa BanksAug 15, 2025
    What to do if my Metabo HPT EC 914S does not run?
    • L
      linda06Aug 15, 2025
      If your Metabo HPT Air Compressor isn't running, first, ensure it's properly plugged in and the power switch is ON. Check for any issues with your extension cord. If a fuse has blown or a breaker has tripped at the power supply, replace the fuse or reset the breaker. If the thermal overload is open, unplug the compressor and wait for it to cool down; the motor will restart automatically. A faulty pressure switch may also be the cause, requiring replacement.
  • C
    Christina BarnettAug 18, 2025
    How to reduce moisture in the air discharge from Metabo HPT EC 914S Air Compressor?
    • A
      Andrew PittmanAug 18, 2025
      If there is excessive moisture in the air discharge from your Metabo HPT Air Compressor, drain the tank to remove water. If humidity is high, move the compressor to an area with less humidity, or use an air line filter to reduce moisture discharge.
  • C
    collin99Aug 21, 2025
    How to fix air leaking from my Metabo HPT EC 914S Air Compressor?
    • O
      odomheatherAug 21, 2025
      If air is leaking from your Metabo HPT Air Compressor, ensure all hose connections are properly sealed with thread sealing tape and tightened. If the air hose is broken or damaged, replace it.
  • B
    Brett BarryAug 25, 2025
    How to stop my Metabo HPT EC 914S Air Compressor from vibrating?
    • R
      Robert BullockAug 25, 2025
      If your Metabo HPT Air Compressor is vibrating, tighten the mounting bolts.
  • O
    opalmerAug 27, 2025
    Why does my Metabo HPT Air Compressor keep blowing fuses?
    • M
      Mikayla Williams MDAug 27, 2025
      If your Metabo HPT Air Compressor keeps tripping the circuit breaker or blowing fuses, make sure the fuse or breaker at the power supply is the correct size and type. Also, using the correct wire gauge and length extension cord is important. If these steps don't solve the issue, the unloader or check valve may be defective, and you should take the compressor to a service center.
  • G
    Glen SimmonsAug 30, 2025
    Why is my Metabo HPT EC 914S motor humming?
    • K
      Kathy SandersAug 30, 2025
      If your Metabo HPT Air Compressor motor hums but doesn't run properly, start by checking the voltage from the power supply with a voltmeter. Ensure you're using the correct wire gauge and length for the extension cord. If these steps don't resolve the issue, the motor winding might be shorted or the unloader or check valve could be defective, requiring service center assistance.
  • C
    Crystal PayneSep 2, 2025
    Why is my Metabo HPT EC 914S running continuously?
    • B
      Brian JohnsonSep 2, 2025
      If your Metabo HPT Air Compressor is running continuously, verify that the tank drain valve is closed. If it is closed, the pressure switch might be defective, requiring a visit to a service center. Also, consider whether your usage is excessive; the compressor might not be large enough for your tool's air requirements, so decrease the tool run-time.
  • A
    Ann PopeSep 5, 2025
    What to do if the pressure drops when Metabo HPT Air Compressor shuts off?
    • J
      Jordan DunnSep 5, 2025
      If the air receiver pressure drops when your Metabo HPT Air Compressor shuts off, check all connections (fittings, tubing, etc.) for leaks using soapy water; look for bubbles. Ensure the drain valve is tightened. If the check valve is leaking, take the compressor to a service center.
  • O
    ogardnerSep 8, 2025
    Why does the thermal overload keep cutting out on my Metabo HPT EC 914S Air Compressor?
    • C
      Christopher MyersSep 8, 2025
      If the thermal overload protector in your Metabo HPT Air Compressor cuts out repeatedly, check the voltage from the power supply using a voltmeter. Make sure the compressor is in a well-ventilated area to prevent overheating. Also, verify that you are using the correct gauge wire and cord length.
  • M
    Madison ColeSep 12, 2025
    Why is the air output lower than normal on my Metabo HPT Air Compressor?
    • M
      Madeline McdowellSep 12, 2025
      If the air output of your Metabo HPT Air Compressor is lower than normal, the inlet valves might be broken, requiring service at a service center. Also, check the connections for leaks and apply thread sealing tape to fittings before tightening.

Summary

Comprehensive Compressor Safety Instructions

General Operational Safety and Environment

Covers general safety, electrical precautions, work area, and environment.

Personal Protection and Hazard Avoidance

Advises wearing protection, avoiding moving parts, and proper storage.

Advanced Safety Guidelines

Safety: Operational Hazards and Precautions

Hazardous Operations, Materials, and Pressure Safety

Warns against modifications, hot surfaces, flammable materials, and safe pressure settings.

Usage and Maintenance Safety Checks

Essential Electrical Safety Guidelines

Proper Extension Cord Usage

Provides guidelines for selecting and using appropriate extension cords.

Grounding and Electrical Connection Procedures

Details grounding requirements and proper electrical connection.

Electrical Plug and Cord Safety Handling

Compressor Specifications and Key Components

Pump Break-in and Safety Valve Testing

Proper Use of the Air Compressor

Tank Draining and Compressor Storage

Troubleshooting Common Compressor Issues

Troubleshooting Motor and Power Problems

Lists causes and solutions for motor not running, slow, or power issues.

Troubleshooting Pressure and Leakage Issues

Addresses causes for pressure drops, leaks, and continuous running.

Metabo HPT EC 914S Specifications

General IconGeneral
BrandMetabo HPT
ModelEC 914S
CategoryAir Compressor
LanguageEnglish

Related product manuals