10
ENGLISH
After all servicing:
Check to see that all safety
devices are operational.
Make sure that no tools or other
parts remain on or in the
machine.
Compressor does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
Compressor was stopped by
unplugging.
Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins cov
-
ered).
Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
Check valve leaky.
Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7. Repairs
8. Environmental Protection
9. Technical Specifications
Basic 240 Basic 240 (GB 110V)
Suction capacity l/min 220 220
Free air delivery (volume flow rate) l/min 105 105
Filling rate l/min 110 110
Working pressure (compression end pressure) bar 8 8
Pressure vessel volume l 24 24
Pump model F 205 F 205
No. of cylinders 1 1
Motor speed min
-1
2850 2750
Motor capacity kW 1.1 1.35
Supply voltage (50 Hz) V 230 110
Rated current A 6.2 14.0
Fuse protection min. A 10 (time-lag)
Degree of protection IP 20 IP 20
Max. overall cable length when using extension cables:
– at 3 x 1.0 mm
2
lead cross section
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
10
25
50
Dimensions length x width x height mm 615 x 325 x 630 615 x 325 x 630
Weight kg 21.5 21.5
Sound pressure level at 1 m max. dB (A) 85 ± 3 85 ± 3