10
ENGLISH
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the
machine.
Compressor does not run:
• No mains voltage.
− Check cables, plug, outlet and
mains fuse.
• Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
• Compressor was stopped by
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
• Motor has overheated, caused by
insufficient cooling (cooling fins cov
-
ered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7. Repairs
8. Environmental Protection
9. Technical Specifications
Basic 240 Basic 240 (GB 110V)
Suction capacity l/min 220 220
Free air delivery (volume flow rate) l/min 105 105
Filling rate l/min 110 110
Working pressure (compression end pressure) bar 8 8
Pressure vessel volume l 24 24
Pump model F 205 F 205
No. of cylinders 1 1
Motor speed min
-1
2850 2750
Motor capacity kW 1.1 1.35
Supply voltage (50 Hz) V 230 110
Rated current A 6.2 14.0
Fuse protection min. A 10 (time-lag)
Degree of protection IP 20 IP 20
Max. overall cable length when using extension cables:
– at 3 x 1.0 mm
2
lead cross section
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
10
25
50
Dimensions length x width x height mm 615 x 325 x 630 615 x 325 x 630
Weight kg 21.5 21.5
Sound pressure level at 1 m max. dB (A) 85 ± 3 85 ± 3