ENGLISH en
13
ADanger!
Prior to all servicing:
Unplug.
7.1 Troubleshooting guide
Pump does not run:
No mains voltage.
Check cables, plug, outlet and mains
fuse.
Mains voltage too low.
Use an extension cable with sufficient
conductor diameter.
Motor overheated; motor protection relay
tripped.
Eliminate the cause of overheating
(pump blocked by foreign objects?).
Float switch does not switch pump ON
when water level rises.
Make sure the float switch can move
unrestrictedly. If, despite sufficient mo-
bility of the float switch, the pump does
not switch ON: send the pump to the
service centre in your country.
Motor hums, but does not start:
Pump blocked by foreign objects.
Clean impeller.
Pump runs, but does not pump properly:
Delivery head too high.
Observe max delivery head (see 'Tech-
nical Specifications').
Discharge hose kinked.
Straighten discharge hose.
Discharge hose leaky.
Seal discharge hose; tighten screw fit-
tings.
Pump runs very noisily:
Pump is sucking air.
Ensure there is a sufficient water sup-
ply.
Foreign objects are present (clean
pump).
Manual mode has been set (shallow
water suctioning).
Hold pump at an angle when submerg-
ing.
Pump runs continuously:
Float switch does not reach cut-out posi-
tion.
Make sure the float switch can move
freely.
ADanger!
To avoid risks, only have repairs carried out
by qualified electricians using original Meta-
bo spare parts.
If you have Metabo electrical tools that re-
quire repairs, please contact your Metabo
service centre. For addresses see www.me-
tabo.com.
Observe national regulations on environmen-
tally compatible disposal and on the recycling
of disused machines, packaging and acces-
sories.
Power tools do not belong in the
household rubbish. According to
European Directive 2002/96/EC on
waste electrical and electronic
equipment, electrical waste must
be collected separately and taken
to an environmentally friendly recycling ?fa-
cility.
We, being solely responsible,
hereby declare that these submersible
pumps conform to the standards and direc-
tives specified on the last page.
7. Troubleshooting
8. Repairs
9. Disposal
10. Declaration of Conformity