12
- Turn the switch button (6) to position .
- Turn the chisel until it engages.
When a chisel is fitted, only operate the
machine in the chiselling operating mode .
7.4 Switching On and Off
To switch on
the machine, press the trigger switch
(7). To switch off
release the trigger switch (7).
The power tool should be cleaned regularly, often
and thoroughly through all air vents using a vacuum
cleaner or by blowing in dry air. Prior to this
operation, separate the power tool from the power
source and wear protective glasses and dust mask.
A damaged dust protection cap (4) must be
replaced immediately.
To replace the dust protection cap (4) slide the tool
lock (5) back. Grasp the dust protection cap and pull
firmly forwards and off. Fit the new dust protection
cap onto the spindle at an angle and press hard to
secure.
Use only genuine Metabo accessories.
Use only accessories which fulfil the requirements
and specifications listed in these operating
instructions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
A defective mains cable must only be replaced with
a special, original mains cable from metabo, which
is available only from the Metabo service.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Directive 2012/
19/Eu on waste electrical and electronic equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recycling.
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
P
1
=Rated input power
P
2
=Power output
n
1
=No-load speed
D
1
=Max. drilling diameter in concrete with
impact masonry bits
D
2
=Max. drilling diameter in concrete with
impact core cutters
s
max
=Maximum impact rate
W=Single impact force
C=Number of chisel positions
m =Weight without mains cable
Measured values determined in conformity with
EN 62841.
Machine in protection class II
~ AC Power
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. Depending on the operating
conditions, the condition of the power tool or the
accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks
and periods when the load is lower. Based on the
adjusted estimates, arrange protective measures
for the user e.g. organisational measures.
Vibration total value
(vector sum of three directions)
determined in accordance with EN 62841:
a
h, HD
=Vibration emission value (hammer drilling
into concrete)
a
h, Cheq
=Vibration emission value (chiselling)
K
h,HD/Cheq
= Uncertainty (vibration)
Typical A-effective perceived sound levels
:
L
pA
= sound-pressure level
L
WA
= acoustic power level
K
pA
, K
WA
= uncertainty
Values measured as per EN 62841.
L
WA(M)
=Measured acoustic power level as per
2000/14/EG
L
WA(G)
=Guaranteed acoustic power level as per
2000/14/EC
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!
8. Cleaning, Maintenance
9. Accessories
10. Repairs
11. Environmental Protection
12. Technical Specifications