MD 9020 Electrical & Electronic DMM Specification
19
***Specified with battery voltage above 2.8V (approximately half full battery). Accuracy
decreases gradually to 12% at low battery warning voltage of approximately 2.4V
Hz Frequency
RANGE* Accuracy**
50.00Hz, 500.0Hz,
5.000kHz, 50.00kHz,
500.0kHz, 1.000MHz
0.5%+4d
*Additional 5.000Hz range accuracy & sensitivity are not specified
**Accuracy is specified at < 20VAC rms
Input Signal : Square wave with duty cycle > 40% & < 70%; or Sine wave Vrms AC
Sensitivity:
10Hz--20Hz : > Sine 0.9Vrms;
20Hz--500kHz : > 2.6Vp; or Sine 1.9Vrms;
500kHz--1MHz : > 4.2Vp; or Sine 3Vrms
Update Rate : 2 per second nominal