IC equipment
IC equipment: Inline-Ultrafiltration (6.5330.110)
Manual
8.110.8037EN / 2014-02-20
Question and Answer IconNeed help?

Do you have a question about the Metrohm 6.5330.110 and is the answer not in the manual?

Summary

1 Introduction

1.1 Description of the IC equipment: Inline-Ultrafiltration

Details the IC equipment Inline-Ultrafiltration, its ultrafiltration cell, and its use for sample filtration.

1.2 About the documentation

Outlines the manual's scope, covering assembly, maintenance, and connections, excluding peristaltic pump setup.

1.3 Symbols and conventions

Explains symbols and formatting used in the documentation for clarity and safety.

2 Overview

2.1 Parts of the IC equipment: Inline-Ultrafiltration

Illustrates and lists the various parts of the IC equipment: Inline-Ultrafiltration.

2.2 Components of the ultrafiltration cell

Details the individual components that make up the ultrafiltration cell.

2.3 Connectors of the ultrafiltration cell

Describes the connectors and their functions for the ultrafiltration cell.

2.4 Mode of operation for ultrafiltration

Explains the working principle of the ultrafiltration process with the IC equipment.

3 Installation

3.1 Preparing the ultrafiltration cell

Guides through preparing the ultrafiltration cell, including inserting the filtration membrane and removing components.

3.2 Connecting the ultrafiltration cell

Details how to establish capillary connections for the ultrafiltration system.

3.3 Inserting the ultrafiltration cell

Provides instructions on how to fasten and insert the ultrafiltration cell into the system.

3.4 Deaerating the ultrafiltration cell

Explains the process of removing air from the filtration cell and capillaries.

4 Operation and maintenance

4.1 Operation

Covers the operation of the IC equipment, focusing on the filtration membrane.

4.2 Maintenance

Details procedures for maintaining the filtration system, including replacing the filtration membrane.

5 Technical specifications

5.1 Ultrafiltration cell (6.2729.110)

Provides technical details for the Ultrafiltration cell, including material and solvent compatibility.

5.2 Filtration membrane (6.2714.020)

Lists specifications for the Filtration membrane, such as pore diameter and material.

5.3 Dialysis membrane (6.2714.030)

Provides technical specifications for the Dialysis membrane, including pore diameter and material.

6 Accessories

Downloading the accessories list

Explains how to find and download the accessories list from the manufacturer's website.

Summary

1 Introduction

1.1 Description of the IC equipment: Inline-Ultrafiltration

Details the IC equipment Inline-Ultrafiltration, its ultrafiltration cell, and its use for sample filtration.

1.2 About the documentation

Outlines the manual's scope, covering assembly, maintenance, and connections, excluding peristaltic pump setup.

1.3 Symbols and conventions

Explains symbols and formatting used in the documentation for clarity and safety.

2 Overview

2.1 Parts of the IC equipment: Inline-Ultrafiltration

Illustrates and lists the various parts of the IC equipment: Inline-Ultrafiltration.

2.2 Components of the ultrafiltration cell

Details the individual components that make up the ultrafiltration cell.

2.3 Connectors of the ultrafiltration cell

Describes the connectors and their functions for the ultrafiltration cell.

2.4 Mode of operation for ultrafiltration

Explains the working principle of the ultrafiltration process with the IC equipment.

3 Installation

3.1 Preparing the ultrafiltration cell

Guides through preparing the ultrafiltration cell, including inserting the filtration membrane and removing components.

3.2 Connecting the ultrafiltration cell

Details how to establish capillary connections for the ultrafiltration system.

3.3 Inserting the ultrafiltration cell

Provides instructions on how to fasten and insert the ultrafiltration cell into the system.

3.4 Deaerating the ultrafiltration cell

Explains the process of removing air from the filtration cell and capillaries.

4 Operation and maintenance

4.1 Operation

Covers the operation of the IC equipment, focusing on the filtration membrane.

4.2 Maintenance

Details procedures for maintaining the filtration system, including replacing the filtration membrane.

5 Technical specifications

5.1 Ultrafiltration cell (6.2729.110)

Provides technical details for the Ultrafiltration cell, including material and solvent compatibility.

5.2 Filtration membrane (6.2714.020)

Lists specifications for the Filtration membrane, such as pore diameter and material.

5.3 Dialysis membrane (6.2714.030)

Provides technical specifications for the Dialysis membrane, including pore diameter and material.

6 Accessories

Downloading the accessories list

Explains how to find and download the accessories list from the manufacturer's website.

Metrohm 6.5330.110 Specifications

General IconGeneral
CategoryMedical Equipment
Electrode TypeCombined pH electrode
Electrolyte3 mol/L KCl
Shaft MaterialGlass
Product Name6.5330.110
pH Range0 - 14
Sensor TypepH electrode