Metso NE727 Specifications

General IconGeneral
CategoryValve Positioners
Supply Pressure1.4 - 7 bar (20 - 100 psi)
Output PressureEqual to supply pressure
Ambient Temperature Range-40 to +85 °C (-40 to +185 °F)
Enclosure RatingIP66/NEMA 4X
Hazardous Area CertificationATEX, IECEx, CSA

Summary

Introduction

Principle of Operation

Explains the torque balance mechanism of the positioner using force coil and feedback spring.

Technical Specifications

Details input signal, split ranges, input resistance, turning angle, supply pressure, and environmental specs.

Safety Precautions

Critical warnings regarding performance limitations, pressurized components, and live voltage.

Mounting on the Metso Actuator

Installing Positioner NE700/S1 on Metso Actuators with VDI/VDE 3845 Mounting Face

Step-by-step guide for mounting the positioner on specific Metso actuator mounting faces.

Instrument Air Supply

Requirements for clean, dry, oil-free instrument air supply and its pressure specifications.

Input Signal and Directions of Operation

Changeover Piece

Instructions on setting the changeover piece for direct (D) or reverse (R) function.

Cam Plate

Explanation of cam plate markings for signal ranges and direction of rotation for operation.

Preliminary Actions for the Adjustment

Basic Adjustment

α₀ Adjustment

Maintenance

Troubleshooting

Electrical Defects

How to diagnose electrical issues using measurements and possible faults.

Mechanical Defects

Identifies common mechanical problems and their potential causes.