Operation Manual
Multi-parameter
Transmitter M400
Transmitter Multiparameter M400
52 121 378

Table of Contents

Other manuals for Mettler Toledo M400

Question and Answer IconNeed help?

Do you have a question about the Mettler Toledo M400 and is the answer not in the manual?

Mettler Toledo M400 Specifications

General IconGeneral
IP RatingIP65
Inputs1 or 2 analog inputs
Outputs2 relay outputs, 1 analog output
Power Supply24 V DC, 100…240 V AC
Communication ProtocolsPROFIBUS
Measurement ParameterspH, ORP, conductivity, dissolved oxygen, temperature
ApprovalsATEX, IECEx
Operating Temperature-20…60 °C (-4…140 °F)
Measurement RangeDepends on sensor connected
AccuracyDepends on sensor connected
Temperature CompensationAutomatic
Output SignalFOUNDATION Fieldbus, PROFIBUS PA
Dimensions96 x 96 mm
Storage Temperature-30°C to +70°C

Summary

1 Introduction

2 Safety instructions

2.1 Definition of equipment and documentation symbols and designations

Defines symbols and designations used in the manual for safety.

2.2 Correct disposal of the unit

Provides guidance on proper disposal of the transmitter according to environmental regulations.

2.3 Ex Classification

Details the Ex classification for M400 transmitters and associated approvals.

3 Unit overview

3.1 Overview 1/2DIN

Provides a visual overview of the M400 1/2DIN model components.

3.2 Control/Navigation Keys

Explains the function of control and navigation keys for operating the transmitter.

4 Installation instruction

4.1 Unpacking and inspection of equipment

Details the procedure for unpacking and inspecting the transmitter upon arrival.

4.1.1 Panel cutout dimensional information – 1/2DIN models

Provides dimensions for the panel cutout required for 1/2DIN models.

4.1.2 Installation procedure

Outlines the steps for installing the transmitter for wall or pipe mounting.

4.2 Connection of power supply

Explains how to connect the power supply to the transmitter.

4.3 Connector PIN definition

Details the pin assignments for various connectors on the transmitter.

4.4 Connection of ISM (digital) sensors

Provides instructions for connecting ISM digital sensors to the transmitter.

4.5 Connection of analog sensors

Details how to connect analog sensors to the transmitter.

6 Quick Setup

7 Sensor Calibration

7.1 Enter Calibration Mode

Explains how to enter the calibration mode on the transmitter.

7.2 Conductivity calibration for two- or four-electrode sensors

Describes the process for calibrating conductivity sensors.

7.7 pH calibration

Details the procedures for calibrating pH sensors.

7.8 ISFET calibration

Explains the calibration process for ISFET sensors.

7.9 Dissolved carbon dioxide calibration

Describes the calibration process for dissolved carbon dioxide sensors.

7.11 Sensor temperature calibration (only for analog sensors)

Explains how to calibrate the sensor temperature for analog sensors.

7.12 Edit sensor calibration constants (only for analog sensor)

Allows editing of sensor calibration constants for analog sensors.

7.13 Sensor verification

Details the process for verifying sensor calibration.

8 Configuration

8.1 Enter configuration mode

Explains how to access the configuration menu.

8.2 Measurement

Section for configuring measurement parameters.

8.2.1 Channel Setup

Configures the sensor channel setup for analog or ISM sensors.

8.2.3 Parameter related settings

Allows adjustment of measurement and calibration parameters for various sensors.

8.3 Analog outputs

Configuration options for the transmitter's analog outputs.

8.4 Set points

Allows configuration of set points for alarms and control.

8.5 Alarm/Clean

Configuration for alarm and cleaning cycle functions.

8.6 ISM set up (available for pH and oxygen ISM sensors)

Setup and configuration options for ISM sensors.

8.7 Display

Configuration options for the transmitter's display.

8.8 Hold analog outputs

Controls holding analog outputs during calibration or digital input activation.

9 System

9.1 Set Language

Allows selection of the display language.

9.2 USB

Configuration options for the USB hold function.

9.3 Passwords

Manages operator and administrator passwords and menu access.

9.4 Set/Clear lockout

Enables or disables the transmitter lockout functionality.

9.5 Reset

Provides options to reset system, meter, or analog calibration.

9.6 Set date & time

Allows setting the current date and time on the transmitter.

10 PID setup

10.1 Enter PID setup

Explains how to enter the PID setup menu.

10.2 PID auto /manual

Allows selection between automatic or manual PID operation.

10.3 Mode

Selection of control modes using relays or analog outputs for PID.

10.4 Tune parameters

Assigns measurements and sets PID tuning parameters.

10.5 PID display

Enables display of PID control status in normal measurement mode.

11 Service

11.1 Diagnostics

Provides diagnostic functionality for troubleshooting transmitter issues.

11.2 Calibrate

Options to calibrate the transmitter, analog outputs, and unlock calibration.

12 Info

12.1 Messages

Retrieves and clears recent error and warning messages.

12.2 Calibration data

Displays calibration constants for each sensor.

12.3 Model/Software revision

Shows transmitter part number, model, serial, firmware, and sensor revision.

12.4 ISM sensor info (available when ISM sensor connected)

Retrieves information about connected ISM sensors.

12.5 ISM sensor diagnostics (available when ISM sensor connected)

Accesses diagnostic functions for connected ISM sensors.

13 Maintenance

13.1 Front panel cleaning

Instructions for cleaning the transmitter's front panel.

14 Troubleshooting

14.1 Changing the fuse

Procedure for safely changing the transmitter's fuse.

14.2 Cond (resistive) Error messages /Warning- and Alarm list for Cond sensors

Lists error, warning, and alarm messages for resistive conductivity sensors.

14.3 Cond (inductive) Error messages / Warning- and Alarm list

Lists error, warning, and alarm messages for inductive conductivity sensors.

14.4 pH Error messages /Warning- and Alarm list

Lists error, warning, and alarm messages for pH sensors.

14.5 Amperometric O2 Error messages /Warning- and Alarm list

Lists error, warning, and alarm messages for amperometric O2 sensors.

14.6 Optical O2 Error messages/Warning- and Alarm list

Lists error, warning, and alarm messages for optical O2 sensors.

14.7 TDL /Warning- and Alarm list

Lists warning and alarm messages for TDL sensors.

15 Accessories and Spare Parts

16 Specifications

16.1 General specifications

Provides general technical specifications for the transmitter.

16.2 Electrical specifications

Details the electrical specifications of the transmitter.

16.3 Mechanical specifications

Provides the mechanical specifications and dimensions of the transmitter.

16.4 Environmental specifications

Lists the environmental operating conditions for the transmitter.

16.5 Ex Classification

Details the Ex classification and approvals for the transmitter.

18 Warranty

19 Buffer tables

19.1 Standard pH buffers

Lists standard pH buffer values for automatic recognition.

19.1.1 Mettler-9

Provides Mettler-9 pH buffer values at different temperatures.

19.1.2 Mettler-10

Provides Mettler-10 pH buffer values at different temperatures.

19.1.3 NIST Technical Buffers

Provides NIST Technical pH buffer values at different temperatures.

19.1.4 NIST standard buffers (DIN and JIS 19266: 2000–01)

Provides NIST standard pH buffer values at different temperatures.

19.1.5 Hach buffers

Provides Hach pH buffer values up to 60 °C.

19.1.6 Ciba (94) buffers

Provides Ciba (94) pH buffer values at different temperatures.

19.1.7 Merck Titrisole, Riedel-de-Haën Fixanale

Provides Merck Titrisole pH buffer values at different temperatures.

19.1.8 WTW buffers

Provides WTW pH buffer values at different temperatures.

19.1.9 JIS Z 8802 buffers

Provides JIS Z 8802 pH buffer values at different temperatures.

19.2 Dual membrane pH electrode buffers

Lists buffer values for dual membrane pH electrodes.

19.2.1 Mettler-pH/pNa buffers (Na+ 3.9M)

Provides Mettler-pH/pNa buffer values at different temperatures.