Enclosure Rating | IP65 |
---|---|
Measurement range pH | 0 - 14 pH |
Accuracy pH | ±0.01 pH |
Accuracy ORP | ±1 mV |
Accuracy Conductivity | ±0.5% of reading |
Display | LCD |
Inputs | 4-20 mA, HART, RS-485 |
Output | 4-20 mA, HART |
Power Supply | 24 VDC |
Mounting | Wall |
Measurement range ORP | -2000 - +2000 mV |
Measurement range Dissolved Oxygen | 0 to 20 ppm |
Temperature range | -20 to 55°C |
Accuracy Dissolved Oxygen | ±0.1 mg/L |
Defines safety symbols and designations used in the manual and on equipment.
Provides guidance on proper disposal of the transmitter unit according to regulations.
Details the physical layout and components of the 1/4DIN model.
Details the physical layout and components of the 1/2DIN model.
Explains the functions of the transmitter's control and navigation keys.
Guidance on how to unpack and check the transmitter for completeness and damage.
Detailed instructions for installing the 1/4DIN transmitter model.
Detailed instructions for installing the 1/2DIN transmitter model.
Instructions for connecting the power supply to the transmitter.
Defines the terminal connections for sensors and outputs.
Steps for correctly assembling sensors and their cables.
Steps to put the transmitter into operation after installation.
Procedure for safely removing the transmitter from operation.
Procedure to access the sensor calibration menu.
Details for calibrating conductivity and resistivity sensors.
Instructions for calibrating dissolved oxygen sensors.
Procedures for calibrating pH sensors, including one-point and two-point modes.
Instructions for performing ORP sensor calibration.
Details for calibrating ozone sensors.
Procedure for verifying sensor performance and readings.
Steps to access the configuration menu.
Configuration options related to sensor measurements.
Configuration of the transmitter's analog output signals.
Configuration of setpoints for alarms and relay activation.
Configuration of alarm events and automatic cleaning cycles.
Settings for configuring the display layout and options.
Option to configure the display language.
Settings related to USB connection and data handling.
Configuration and management of operator and administrator passwords.
Enables or disables the transmitter lockout functionality.
Allows resetting system settings or analog calibration.
Tools for diagnosing transmitter status and components.
Options for calibrating analog outputs and unlocking calibration.
Access for Mettler Toledo service personnel.
Displays recent system messages and alarms.
Shows calibration constants for each sensor.
Displays transmitter part number, serial, and software versions.
Provides details about the connected sensor.
Instructions for cleaning the transmitter's front panel.
List of error, warning, and alarm messages for conductivity/resistivity.
List of error, warning, and alarm messages for oxygen measurement.
List of error, warning, and alarm messages for pH measurement.
List of error, warning, and alarm messages for ORP measurement.
Explains how warnings and alarms are indicated on the display.
Overall technical specifications for the transmitter.
Technical details on power supply, outputs, and digital interfaces.
Physical dimensions, weight, material, and enclosure rating.
Operating conditions regarding temperature, humidity, and EMC.
Default configuration values for the 1-channel version.
Default configuration values for the 2-channel version.
Default parameter values for conductivity measurements.
Default parameter values for oxygen measurements.
Default parameter values for pH measurements.
Default parameter values for ORP measurements.
Default parameter values for ozone measurements.
Table of pH values for Mettler-9 buffer solutions at different temperatures.
Table of pH values for Mettler-10 buffer solutions at different temperatures.
Table of pH values for NIST Technical buffer solutions.
Table of pH values for NIST Standard buffer solutions.
Table of pH values for Hach buffer solutions at different temperatures.
Table of pH values for Ciba (94) buffer solutions at different temperatures.
Table of pH values for Merck Titrisole buffer solutions.
Table of pH values for WTW buffer solutions at different temperatures.