EasyManua.ls Logo

Metz Eta Plus ELC N6 - User Manual

Metz Eta Plus ELC N6
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
UV-
TECHNOLOGY
Technical Documentation
ELC
®
N6 / ELC
®
N8 / ELC
®
N10
GB
£¤
eta plus electronic gmbh
Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22 - 60 02-80, Fax +49 (0) 70 22 6 58 54
Postfach 1411, D-72604 Nürtingen, e-mail: info@eta-uv.de
––––––––––––––––––––––––––––
Eingetragen unter HRB 724321 AG Stuttgart, USt.-Id.-Nr. DE 146267800
Geschäftsführer: Dr. Peter Schwarz-Kiene
our name is our principle
eta plus electronic gmbh
Lauterstraße 29, 72622 Nürtingen, Telefon +49 7022 6002-80, Fax +49 7022 65854, E-mail: info@eta-uv.de, www.eta-uv.de
Eingetragen unter HRB 724321 AG Stuttgart, USt.-Id.-Nr. DE 146267800, Geschäftsleitung: Uwe Uhlemann, Dr. Markus Roth

Questions and Answers

  • K
    Kaitlin RichAug 4, 2025
    What to do if Metz Eta Plus ELC N6 Industrial Electrical lamp does not fire after being switched on?
    • S
      Steven Velasquez MDAug 4, 2025
      If the Metz Industrial Electrical lamp doesn't fire and the RELEASE relay opens, it could be due to several reasons. First, the lamp might be too hot, so allow it to cool down, and consider improving its cooling. Second, the lamp might not be properly connected; check the plug contacts between the ELC and the lamp. Finally, the lamp itself could be defective, requiring a replacement.
  • J
    jennifer16Aug 17, 2025
    Why is there no RELEASE after switching on the Metz Eta Plus ELC N6 ELC?
    • L
      Lisa CoxAug 17, 2025
      If there's no RELEASE after switching on the Metz Industrial Electrical ELC and the RELEASE relay is open, it could be due to a few reasons. First, ensure the ELC is receiving the correct operating voltage by checking the fuses and voltage at the terminals. Second, if the lamp is switched ON (control input START at HIGH), switch it OFF. If these steps don't resolve the issue, there may be a fault in the ELC.

Summary

Safety

Safety Advice

Outlines crucial safety precautions for installation, operation, and maintenance.

Installation

Mounting of Casing

Specifies requirements for installing the ELC unit in a control cabinet with IP 54 protection.

Connection

Details power connection, wiring plan, and shielding requirements for the ELC.

Mains Connection

Explains the location and requirements for the ELC's mains connection, including torque specs.

Connecting the Lamp Feeder Cable

Guides on connecting the lamp feeder cable, including connector assembly and cable preparation.

Control Current Connections

Details how control wires are connected to the underside connectors and pin assignments.

Explanations of Control Functions for ELC

Earth Fault Control

Details the earth fault detection system and the function of the ES relay.

Operation of ELC

Troubleshooting

Repair ELC

States that only the manufacturer is permitted to repair the ELC and provides contact information.