NOVA SERIES
REDUCED CLEARANCE KIT
OWNERS MANUAL
Safety Notice: Please save these instructions for future reference. Please check our
website for the most up to date version of this manual. Please read this entire manual
before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death. Contact local building or fire officials
about restrictions and installation inspection requirements in your area. Do not install
Nova in a mobile home!
Manufactured by:
MF Fire, Inc.
3031 Washington Blvd STE G,
Baltimore, MD, USA
Report Number F20-590
Question and Answer IconNeed help?

Do you have a question about the MF FIRE NOVA Series and is the answer not in the manual?

Summary

Safety Precautions and Manual Introduction

General Safety Notice

Crucial safety instructions for reference, emphasizing website checks for updates and reading the entire manual before installation.

Usage as a Supplement

This manual serves as a supplement to the Nova and Nova Tower Owner's Manuals for reduced wall clearance.

Risks of Damaged or Removed Components

Warning that the stove cannot be operated if kit parts are damaged or removed, citing risks of property damage or injury.

Reduced Clearance Kit Components and Installation

Pipe Shield Installation

Instructions for placing the pipe shield atop the stove, centered behind the double wall connector pipe.

Reduced Clearance Air Duct Installation

Guidance on hanging the reduced clearance air duct from the two rear air duct bolts on the stove.

Overview

This document serves as the owner's manual for the Nova Series Reduced Clearance Kit, a supplementary component designed to enhance the safety and versatility of Nova and Nova 2 series wood-burning stoves. The primary function of this kit is to reduce the required back wall clearance to combustible materials, allowing for more flexible installation options in various settings. By incorporating this kit, users can safely position their Nova or Nova 2 stove closer to combustible walls than would otherwise be permitted by the standard stove clearances, without compromising safety. This is particularly beneficial in smaller spaces or when specific room layouts necessitate a reduced clearance installation.

The kit is intended to be used in conjunction with the main owner's manuals for the Nova and Nova Tower series, or the Nova 2 and Nova 2 Tower series. It is crucial that users consult both the relevant stove owner's manual and this reduced clearance kit manual to ensure a complete understanding of all installation and operational requirements. The reduced clearance kit itself is comprised of two main parts: a pipe shield and a reduced clearance air duct. These components work in tandem to manage heat dissipation and maintain safe temperatures around combustible surfaces.

One of the key usage features of this kit is its ability to facilitate a "top vent, ceiling exit" configuration, which is a common and often preferred method for venting wood stoves. The manual provides a detailed diagram illustrating the clearances required for this setup, including sidewall to unit, backwall to unit, sidewall to connector, and backwall to connector measurements. These measurements are provided in both inches and millimeters for clarity and precision, ensuring that installers can accurately determine the safe distances from combustible materials. The specific clearance values vary slightly depending on whether the kit is used with a Nova/Nova Tower stove (requiring a double wall connector pipe with reduced clearance kit) or a Nova 2/Nova 2 Tower stove (requiring a double connector pipe with reduced clearance kit). This differentiation highlights the kit's adaptability to different stove models within the Nova series.

The installation process for the reduced clearance kit is straightforward, focusing on the correct placement of its two components. The pipe shield is designed to be placed atop the stove, specifically centered behind the double wall connector pipe. A critical detail for its placement is that it must be set back by ½ inch off the back of the double wall pipe. The manual explicitly states that no additional securement is needed for the pipe shield, simplifying its installation. This component plays a vital role in protecting the area directly above the stove from excessive heat, which is particularly important when reducing clearances to combustible ceilings or walls.

The second component, the reduced clearance air duct, is designed to be hung from two existing rear air duct bolts already installed on the rear of the stove. This attachment method ensures a secure and proper fit without requiring additional drilling or complex fastening procedures. The air duct works to channel air, further managing heat distribution and maintaining safe temperatures around the stove's rear, where reduced clearances are often most critical. The manual provides a visual aid, an image of the stove with the pipe shield and reduced clearance air duct installed, clearly labeling each component to assist users in correct identification and placement.

A crucial aspect emphasized throughout the manual is safety. The document begins with a prominent safety notice, urging users to save the instructions for future reference and to check the manufacturer's website for the most up-to-date version of the manual. It stresses the importance of reading the entire manual before installation and use, warning that failure to follow instructions can lead to property damage, bodily injury, or even death. This highlights the serious nature of wood stove installation and the critical role of proper clearance management.

The manual also advises users to contact local building and fire officials to inquire about specific restrictions and installation inspection requirements in their area. This underscores the importance of adhering to local codes and regulations, which may vary and could impact the legality and safety of an installation. A specific prohibition against installing Nova stoves in mobile homes is also noted, indicating certain limitations on the kit's applicability.

Maintenance features, while not extensively detailed for the kit itself, are implicitly linked to the overall maintenance of the stove. The integrity of the reduced clearance kit components is paramount for continued safe operation. The manual explicitly states that if any portions of the Nova Series Reduced Clearance Kit are damaged or removed, the stove cannot be operated unless clearances to combustibles are re-evaluated based on guidance in the respective product owner's manual. This implies that regular inspection of the pipe shield and air duct for damage or displacement is a necessary part of routine maintenance. Any damage to these components would necessitate their repair or replacement to maintain the reduced clearance benefits and ensure safety.

The kit is available in two distinct versions, tailored to specific Nova stove models: the Nova Reduced Clearance Kit (MF02-RCK) and the Nova 2/Nova 2 Tower Reduced Clearance Kit (MF03-RCK). Both kits include the Nova Series Pipe Shield (0364-000-C), but they differ in the specific reduced clearance air duct provided: the Nova Reduced Clearance Air Duct (N92) for the MF02-RCK and the Nova 2 Reduced Clearance Air Duct (N93) for the MF03-RCK. This modular approach ensures compatibility and optimized performance across the different Nova stove models.

In summary, the Nova Series Reduced Clearance Kit is a vital accessory for Nova and Nova 2 series wood stoves, designed to safely minimize the required distance between the stove and combustible walls or ceilings. Its function is to enhance installation flexibility while maintaining rigorous safety standards through its pipe shield and air duct components. Usage involves careful placement according to precise measurements and adherence to all safety warnings. Maintenance primarily involves ensuring the integrity of the kit's components, as damage or removal necessitates a re-evaluation of clearances to prevent hazards. This kit is a testament to thoughtful design aimed at improving user experience and installation options for wood-burning stoves.

MF FIRE NOVA Series Specifications

General IconGeneral
ModelNOVA Series
TypeIndoor Fireplace
Fuel TypeEthanol
Burn TimeUp to 5 hours
MaterialGlass
Safety FeaturesFlame regulation