EasyManua.ls Logo

MG MG600S User Manual

MG MG600S
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LASER RANGEFINDER
INSTRUCTIONS
Changing Modes
Pressing and releasing black button switches between MG-Lock
Measurement Mode (MD) which locks onto pin, and MG-Lock
Recommended Distance Mode (RD) which locks onto pin & adjusts for
slope.
Vibrating MG-Lock Conrmation Feature
In MG-Lock (Measurement and Recommended Distance) Modes, a
vibrating pulse gives tactile feedback that the rangender has locked on
to the targeted object.
M
Power On & Take
Measurement
Hold red button for
approx 1 sec. (Automatically
shuts o after 1 minute, no manual o.)
Subsequent press and release of red button takes a measurement.
MG-Lock Recommended Distance Mode (Scan RD)
(Slope)
Recommended Distance Mode
(indicated by RD on LCD and
icon) adjusts distance based
on angle of the slope. Aim, then
press and release red button.
Distance and slope angle readings
will alternate in viewnder, both
display simultaneously on side LCD
panel. (This mode also includes MG-
Lock, indicated by icon, which locks onto a target with something
(like a bunker or tree) behind it.
^
^
^
|
Scan
- - -
Y
150 yds.
150 yds. (uphill)
X
Example: Measurement modes (MD and standard) will measure 150
yards for both the level and uphill distances resulting in the uphill shot
falling short by several yards. RD mode will instead adjust the distance
higher on the uphill shot, or lower on a downhill shot,
telling you the distance the shot will play.
(For illustrative purposes only. Not to scale.)
(Continued on Reverse Side)
M
Question and Answer IconNeed help?

Do you have a question about the MG MG600S and is the answer not in the manual?

MG MG600S Specifications

General IconGeneral
BrandMG
ModelMG600S
CategoryMeasuring Instruments
LanguageEnglish

Summary

LASER RANGEFINDER INSTRUCTIONS

Power On & Take Measurement

Instructions for powering on the device and taking measurements using the red button. Automatic shut-off included.

Changing Modes

How to switch between MG-Lock Measurement Mode (MD) and Recommended Distance Mode (RD) using the M button.

Vibrating MG-Lock Confirmation Feature

Tactile feedback provided by the rangefinder when it locks onto the target in MG-Lock modes.

MG-Lock Recommended Distance Mode (Scan RD) (Slope)

Recommended Distance Mode (Slope)

Adjusts distance based on slope angle; displays distance and slope readings alternatingly or simultaneously.

RD Mode Example

Illustrates RD mode adjusting for uphill/downhill shots, showing the effective distance to play.

MG-Lock Measurement Mode (Scan MD) (No slope)

MG-Lock Measurement Mode (No slope)

MG-Lock locks onto targets with objects behind them, scanning for distance. Indicated by the icon.

Low Battery Alert & Replacing Battery

Low Battery Alert

Alerts users when the battery is low, indicated by a specific icon in the viewfinder.

Replacing Battery

Step-by-step guide on how to replace the 3V (CR2) battery located at the bottom of the device.

Specifications

Technical Specifications

Details key features like slope recommendation, MG-Lock, vibration, lens, magnification, view angle, and dimensions.

Related product manuals