Bio-sensing radar
60GMilimeter wave
MicRadar Technology (Shenzhen) Co. ,LTD
R60AMP1-Multi-person trajectory radar
Datasheet(Ver.1.0)
Question and Answer IconNeed help?

Do you have a question about the MicRadar R60AMP1 and is the answer not in the manual?

Summary

Product Overview

Model Description

Details the specific model number and its designation.

Electrical Characteristics and Parameters

Detection Angle and Distance

Specifies the radar's angular coverage and maximum detection distances.

Electrical Characteristics

Key electrical parameters including voltage, current, and temperature ratings.

RF Performance

Details the radio frequency operational parameters such as frequency and transmit power.

Module Size and Pin Description

Module Size and Package

Provides the physical dimensions and package type of the radar module.

Pin Description

Details the function of each pin on the radar module's interface.

Wiring Diagrams

Illustrates how to connect the radar module to other systems.

Main Work Performance

Radar Module Working Range

Describes the coverage area and effective range of the radar beam.

Main Functions and Performance

Outlines the primary functions and key performance metrics of the radar.

Main Function

Details the primary capability of real-time multi-person trajectory detection.

Main Performance Parameters

Lists specific performance metrics like accuracy, distance, and tracking limits.

Radar Work and Installation

Installation Method

Provides recommended methods for installing the radar module.

How the Radar Works

Explains the operational principle and data processing of the radar.

Multiplayer Tracking Mode

Details the mode for tracking multiple people simultaneously.

Typical Application Modes

Home Appliance Application

Describes applications for home appliances using the radar module.

Security Management Application

Describes applications for security management using the radar module.

Precautions and Safety

Start Time

Information on the required power-on stabilization time for the module.

Effective Detection Distance

Factors affecting the radar's detection range and its variability.

Radar Biodetection Performance

Performance aspects related to bio-detection and signal processing.

Power Supply Requirements

Critical specifications for the power supply to ensure proper module operation.

Disclaimer and Contact Information

Disclaimer

Legal statement regarding the document's accuracy and company liability.

Contact Details

Information for contacting the manufacturer, MicRadar Technology.

Copyright Statement

Details regarding copyright ownership of the document's content.

Historical Version Update Instructions

Records of past revisions and updates to the document.

Overview

The MicRadar R60AMP1 is a 60GHz millimeter wave bio-sensing radar module designed for multi-person trajectory tracking. This module is based on a one-shot three-receiver antenna configuration, utilizing algorithms to control a specific angular range. It accurately scans real-time direction and distance changes of multiple targets, refreshing three-dimensional data within its effective field of view (FOV).

Function Description

The R60AMP1 radar module is capable of detecting multiple target states, providing real-time angle changes and distance information simultaneously. It offers real-time multi-target trajectory tracking within a defined detection range and can lock onto the coordinate positions of stationary personnel.

Key working characteristics of this radar module include:

  • FMCW Radar Detection: It operates based on Frequency Modulated Continuous Wave (FMCW) signals, which allows for precise distance and velocity measurements.
  • Real-time Multi-target Trajectory Tracking: The module can track the movement paths of multiple individuals in real-time.
  • Personnel Detection Distance: It can track personnel trajectories up to 10 meters when installed horizontally. For stationary personnel, it can lock their positions up to 6 meters, also with horizontal installation.
  • Multi-person Tracking Capacity: The module is capable of tracking up to 3 people simultaneously.
  • Angular and Distance Discrimination: For multiple people tracking, it can distinguish targets with a minimum angular separation of 20° and a minimum distance separation of 0.5 meters.
  • Wide Horizontal Detection Angle: The multi-person trajectory tracking radar offers a maximum horizontal detection angle of 100°.
  • Biological Object Detection: The module is designed to limit detection to persons with biological characteristics (moving or stationary), effectively eliminating interference from inanimate objects in the environment. It can also detect non-living moving objects.
  • Secondary Development Support: The product supports secondary development, making it adaptable to various scenarios and applications.
  • Universal Communication Interface: It provides a Universal Asynchronous Receiver-Transmitter (UART) communication interface with common protocols.
  • Reserved I/O Groups: Four groups of I/O are reserved, which can be configured for input or output based on user definition, or for simple interface simulation.

Usage Features

The R60AMP1 radar module is suitable for a variety of applications, particularly in home appliance linkage and security management.

Home Appliance Linkage Application:

  • Intelligent Fresh Air Systems: It can be used to adjust fresh air systems based on the number of people detected in a space.
  • Smart Speaker Applications: The module supports sound tracking and senseless adjustment functionalities for smart speakers.

Security Management Application:

  • Security Scene Personnel Management: It is applicable in security scenarios for managing and monitoring personnel.

Installation Method: The recommended installation method for this radar module is horizontal. This method is primarily aimed at detecting target positions of individuals who are walking or sitting still, making it suitable for environments like living rooms or for integration into home appliances. The recommended installation height for the radar is between 1 to 1.5 meters, with the radar installed horizontally and facing forward. The installation inclination should be within ±5°. It is important to ensure that there are no obvious obstructions or coverings directly in front of the radar. The normal direction of the radar should be aligned with the main detection position to ensure that the main beam of the radar antenna covers the detection area and the human activity airspace.

Working Range: The radar module's beam covers a three-dimensional sector area of 100° horizontally and 100° in elevation. The radar's working distance is relatively long in the normal direction of the antenna surface but becomes shorter as the distance from the antenna's normal direction increases. When the radar is installed horizontally, the range of action may be reduced due to the radar beam range and effective radiation space, which should be considered during use.

Multiplayer Tracking Mode: In this mode, the radar module provides real-time information on the position changes of each tracked person within its detection area. It processes statistical analysis to comprehensively evaluate the real-time position status of personnel and the number of people, providing direct results to users. The main state includes real-time output of multi-target personnel location data.

Maintenance Features

Power Supply Requirements: Radar modules have higher power quality requirements compared to conventional low-frequency circuits. The power supply to the module must be free of threshold glitches or ripples, and noise from accessory equipment should be effectively shielded. Proper grounding of the radar module is crucial. Ground noise from other circuits can degrade performance or cause abnormal operation, leading to issues like shortened detection distance or increased false alarm rates. To ensure normal operation of the internal VCO circuit, the power supply should be +5V to +6V, with a voltage ripple of less than or equal to 100mV. The external power supply must also provide sufficient current output capability and transient response capability.

Start-up Time: When the module is initially powered on, it requires a stabilization time of at least 30 seconds. This period allows the internal circuit to completely reset and for the module to fully evaluate environmental noise, ensuring normal operation and the validity of subsequent output parameters.

Effective Detection Distance: The effective detection distance of the radar module is influenced by the target's Radar Cross-Section (RCS) and environmental factors. Therefore, the effective detection distance may vary with changes in the environment and the target. Since this module does not currently have a ranging function, fluctuations in the effective detection distance within a certain range are considered normal.

Radar Biodetection Performance: Human biometrics involve ultra-low frequency and weak reflection signals, requiring a relatively long accumulation process for radar processing. During this accumulation, various factors can affect radar parameters, so occasional detection failures are a normal phenomenon.

Product Packaging: The module has a compact size of 35mm × 31mm × 7.5mm. It features a 2.0mm pitch interface with double rows of pins, including two sets of interfaces (23 and 24 pins).

MicRadar R60AMP1 Specifications

General IconGeneral
CategoryRadar
Frequency24 GHz
TypeFMCW
Frequency Range24.0 - 24.25 GHz
Power Supply12 - 24 V DC
Protection RatingIP67
Operating Temperature-40°C to +85°C