16
Troubleshooting
The impeller of the turbine is blocked by foreign matter.
The gun is partly clogged and only a small amount of water
comes out.
The injection nozzle in the turbine is clogged.
The gun nozzle is too small, compared to the machine model.
Not enough water volume or pressure at the machine inlet.
The gearbox has been damaged.
The machine legs are improperly placed.
The hose is on damp soil or grass which produces too much
drag.
SOLUTION: Remove the turbine cover and clean the
housing.
SOLUTION: Proceed to clean out gun nozzle.
SOLUTION: Disassemble the hose at the turbine entry
and clean out.
SOLUTION: Replace with a larger gun nozzle or a smaller
injection nozzle.
SOLUTION: Increase volume and/or pressure.
SOLUTION: Repair the gearbox.
SOLUTION: Reposition leg to create more friction.
SOLUTION: Wait until the soil has dried or pick up hose
and place blocks of wood under in order to
reduce friction.
IF HOSE DOES NOT WIND UP.....
MACHINE WONT STAY ANCHORED OR SLIDES.....
RECOMMENDATIONS
When moving the machine never exceed the maximum speed of 7 MPH.
If the hose is wound up using the PTO, be certain the gearbox is in the idle or disengaged position, or the
gearbox will be seriously damaged.
At the beginning of each season, completely unwind the hose, leaving only two wraps on the reel.
• ANY MODIFICATION MADE TO ANY PART OF THE MACHINE WILL VOID THE WARRANTY.
If the hose remains unwound on the ground for an extended period of time ( several hours ), it may stick to the
ground. Prior to starting the machine, take a rope and drag underneath the tube from one end to the other,
avoiding any damage due to too much friction.
If the machine is being used on several short elds, the hose may miswrap, or not continue to roll up correctly.
If this happens, unwind the hose with only two wraps remaining on the drum, allowing the machine to rewind
properly.
• THE MACHINE MUST NOT BE OPERATED WITHOUT THE PROTECTION GUARDS
MPORTANT!! Failure to observe these instructions, the use of non original spare parts, or unauthorized