TABLE 6-1: PROGRAMMING/VERIFY TIMING REQUIREMENTS
Note 1: Typical values - not tested in production.
VDD = 5.0V ± 10%, 25 °C ± 5 °C
Parameter Symbol Min. Max. Units
Program mode setup time
T
PS 3.5 4.5 ms
Hold time 1
T
PH1 3.5 ms
Hold time 2
T
PH2 50 μs
Bulk Write time
T
PBW 4.0 ms
Program delay time
T
PROG 4.0 ms
Program cycle time
T
WC 50 ms
Clock low time
T
CLKL 50 μs
Clock high time
T
CLKH 50 μs
Data setup time
T
DS 0—
μs
(1)
Data hold time
T
DH 30
μs
(1)
Data out valid time
T
DV —30
μs
(1)