5NC 150
EN
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
13.Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. The guarantee is valid only on presentation of the guar-
antee card completed by the dealer (see back) confirming date of
purchase or the receipt.
The guarantee covers the device. Batteries and packaging are
not included.
Opening or altering the device invalidates the guarantee.
The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.
14.Technical Specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
According to the Medical Product User Act a biennial technical
inspection is recommended for professional users. Please
observe the applicable disposal regulations.
15.www.microlife.com
Detailed user information about our thermometers and blood pressure
monitors as well as services can be found at
www.microlife.com
.
Type:
Non Contact Thermometer NC 150
Measurement
range:
Body mode: 34.0-42.2 °C / 93.2-108.0 °F
Object mode: 0-100.0 °C / 32-212.0 °F
Resolution:
0.1 °C / °F
Measurement
accuracy:
Laboratory:
±0.2 °C, 36.0 39.0 °C / ±0.4 °F, 96.8 102.2 °F
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
The unit is turned ON and ready for the measure-
ment: 1 short beep.
Complete the measurement: 1 long beep (1 sec.) if
the reading is less than 37.5 °C / 99.5 °F, 10 short
«beep» sounds, if the reading is equal to or greater
than 37.5 °C / 99.5 °F.
System error or malfunction: 3 short «bi» sounds.
Memory:
30 readings recall in the memory mode with a
record of both time and date.
Backlight:
The display light will be GREEN for 4 seconds,
when the unit is turned ON.
The display light will be GREEN for 5 seconds,
when a measurement is completed with a reading
less than 37.5 °C / 99.5 °F.
The display light will be RED for 5 seconds, when
a measurement is completed with a reading equal
to or higher than 37.5 °C / 99.5 °F.
Operating
conditions:
Body mode: 16-40.0 °C / 60.8-104.0 °F
Object mode: 5-40.0 °C / 41-104.0 °F
Storage
conditions:
-20- +5C / -4- +12F
15-95 % relative maximum humidity
Automatic
Switch-off:
Approx. 1 minute after last measurement has been
taken.
Battery:
2 x 1.5 V alkaline batteries; size AAA
Battery
lifetime:
approx. 2000 measurements
(using new batteries)
Dimensions:
141.1 x 43.3 x 36.9 mm
Weight:
90 g (with batteries), 67 g (w/o batteries)
IP Class: IP21
Reference to
standards:
ASTM E1965;
IEC 60601-1; IEC 60601-1-2 (EMC)
;
IEC 60601-1-11
Expected
service life: 5 years or 12000 measurements

Other manuals for Microlife NC 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife NC 150 and is the answer not in the manual?

Microlife NC 150 Specifications

General IconGeneral
TypeRemote sensing
DisplayLCD
Memory functionYes
Thermometer locationEar, Forehead, Oral, Rectal, Underarm

Related product manuals