CDA and Hi-Flo
Instruction Manual
Publication Part No: 10164 Revision: 1

Table of Contents

Questions and Answers

  • S
    Sean BautistaSep 10, 2025
    Why is the breakaway arm loose and not returning to stop on my Micron Spraydome Tank Equipment?
    • N
      Nancy DawsonSep 10, 2025
      If the breakaway arm is loose and doesn't return to stop, the return spring is either detached or broken. Reattach or replace the spring.
  • R
    Rachel EdwardsAug 23, 2025
    Why is the flow rate low or varying in my Micron Tank Equipment?
    • J
      James AlexanderAug 23, 2025
      A low or varying flow rate could be due to several reasons: the tank level may be low or empty, the nozzle or filter may be partially blocked, the hose could be blocked or kinked, the supply pressure might be too low, the pump could be faulty, there might be air in the system, or the spray fluid may be aerated. Refill the tank, clean the nozzle and filters, purge and straighten the hoses, increase the supply pressure to between 1 and 2 bar, replace the pump, purge air from the system, or reduce pump operation or agitation.
  • A
    Alexandra OrtegaAug 25, 2025
    How to troubleshoot Micron Spraydome Tank Equipment when pump and CDA atomiser are not operating?
    • A
      Abigail ThomasAug 25, 2025
      If the pump and CDA atomiser are not operating, the inline switch might be off, the fuse might be blown, or there could be a loose connection at the battery or backplate, or incorrect wiring. Switch on the inline switch and controller, check the system and replace the fuse, check all connections and tighten as necessary, and check the wiring and rewire as necessary.
  • T
    Timothy MurphyAug 26, 2025
    What to do if Micron Spraydome Tank Equipment pump will not operate?
    • M
      Mrs. Donna Welch DDSAug 27, 2025
      If the pump won't operate, it could be due to several reasons: the pump wire might not be connected to the backplate, there might be a loose electrical connection, the diode might be faulty, the diode polarity might be incorrect, the pump motor might be faulty, or the wiring might be incorrect. Connect the pump wire to the backplate 2 pin panel socket, check all connections and tighten as necessary, replace the diode, reverse the diode connections, replace the pump motor, or check the wiring and rewire as necessary.
  • R
    Ricky GreerAug 28, 2025
    What causes a high flow rate in Micron Tank Equipment?
    • V
      Virginia PhamAug 28, 2025
      A high flow rate can be caused by an incorrect or worn nozzle or a supply pressure that is too high. Replace the nozzle with a new one and reduce the supply pressure to between 1 and 2 bar.
  • D
    Dawn BrownAug 29, 2025
    What causes Micron Tank Equipment CDA atomiser not to spin and lamp not to glow?
    • M
      Michelle BrooksAug 29, 2025
      If the CDA atomiser doesn't spin and the lamp doesn't glow, the unit might be switched off, the fuse might be blown, the motor might be faulty, there might be a broken wire or loose connection, a corroded terminal, a blown globe, a loose globe, an incorrect wattage globe, or incorrect wiring. Switch on the inline switch and controller, check the system and replace the fuse, replace the motor, check the wiring, check and tighten the connections, clean or replace the terminal, replace the globe, adjust the globe holder, replace the globe, or check the wiring and rewire as necessary.
  • X
    xcooperSep 18, 2025
    How to fix a stiff breakaway arm on Micron Spraydome?
    • J
      Jeffery WilsonSep 18, 2025
      If the breakaway arm is stiff or does not move, the pivot may have seized. Dismantle, clean and lubricate the pivot.
  • C
    cassandraodonnellSep 12, 2025
    Why is the green wire in my Micron Spraydome control unit overheating or melting?
    • T
      Tracy LeonSep 12, 2025
      If the green wire in the control unit is overheating or melting, the battery polarity is likely incorrect. Replace the green wire and reverse the battery connections.
  • N
    Nathan CarlsonSep 8, 2025
    What to do if Micron Spraydome Tank Equipment CDA spins too fast and lamp does not glow?
    • M
      Mark WebbSep 8, 2025
      If the CDA spins too fast and the lamp doesn't glow, it's likely due to an incorrect wattage globe or reversed globe wiring. Replace the globe and check and rewire the globe wiring.
  • H
    huntchristopherSep 5, 2025
    Why is the CDA spinning slowly on my Micron Spraydome Tank Equipment?
    • J
      Justin GreenSep 5, 2025
      If the CDA spins slowly, it could be due to moisture or corrosion in the motor, or an incorrect wattage globe. Replace the motor or the globe.

Summary

Important Information

Introduction

Technical Specification

Provides detailed specifications for the equipment.

Safety

Warnings and Prohibitions

Lists critical warnings and prohibitions for safe operation.

Mechanical and Electrical Hazards

Details mechanical risks and low voltage electrical safety.

Operator Protection

Specifies PPE requirements for operators.

Working with Pesticides

Outlines safe practices when handling and using pesticides.

Protection of the Environment

Guidelines for environmentally responsible disposal and practices.

Drift Reduction Measures

Details methods and ratings for reducing spray drift.

Installation

Initial Assembly (Spraydome;Undavina)

Step-by-step guide for the initial assembly of specific models.

Preparing for Spraying

Calibration

Setting the Output Flow Rate

Procedures for setting the correct output flow rate for atomisers and nozzles.

Mixing and Filling

Preparing the Spray Mix

Steps for preparing the spray mix, including safety and tank filling.

Spraying

Cleaning

Maintenance

Troubleshooting

Mechanical Faults

Lists common mechanical problems and their solutions.

Hi-Flo Equipment Troubleshooting

Troubleshooting specific issues with Hi-Flo spray heads.

CDA Equipment Troubleshooting

Troubleshooting specific issues with CDA equipment.

Micron Spraydome Series Specifications

General IconGeneral
BrandMicron
ModelSpraydome Series
CategoryTank Equipment
LanguageEnglish

Related product manuals