Service Manual_2018-V2.0
22
11)Replace the compressorand welding the compressor
pipeline.-❿Welding the process pipeline.-⓫Welding the
low-pressure muffler.-⓬Welding the high-pressure
exhaust pipe.
12)Replace the filter, Cu-Fe tubes welding ⓭ used Ag
welding rod, Cu-Cu tubes welding⓮ used Cu welding
rod.
13)Vacuum system,The degree of vacuum below 6Pa.
14)Perfusion refrigerant.