EasyManuals Logo

Midea CBC115CE2S User Manual

Midea CBC115CE2S
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Service Manual_2018-V2.0
28
11. Compressor
11.1Compressor on and off Control specifications
1.1 When one of the following conditions is met, the compressor stops:
1) Tr ≤ Trt
2) The compressor runs continuously for more than 3 hours (Stop 5 minutes);
1.2 When all the following conditions are met, the compressor starts up:
1) Tr ≥Trk;
2) Compressor downtime is more than 5min.
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea CBC115CE2S and is the answer not in the manual?

Midea CBC115CE2S Specifications

General IconGeneral
BrandMidea
ModelCBC115CE2S
CategoryKitchen Appliances
LanguageEnglish

Related product manuals