32801002001 Specifications subject to change without notice. 21
SETTING STATIC PRESSURE WHEN USING
THE RG57 WIRELESS CONTROLLER:
The external static pressure should be selected using the wireless
remote controller (RG57F3(B)/BGEFU1), included with the indoor
unit, by pointing it toward the indoor unit’s Infrared Receiver
typically located inside the control box.
1. Before using the service functions of the remote, turn OFF the
indoor unit with the remote.
2. Turn off the power to the indoor and outdoor units for 3 minutes.
Turn the power back on.
3. Remove the batteries from the RG57 remote and wait for the
remote screen to clear or press any button and the screen will clear.
4. Reinstall the batteries.
5. Within 30 seconds of replacing the batteries, simultaneously press
MODE and TIMER ON for five (5) seconds. You are now in the
SERVICE FUNCTION mode – and the remote display reads F1.
6. Press the DOWN arrow in the center of the remote (labeled
TEMP) to display E9.
7. Press or to select E9.
8. Press MODE to set the airflow rate in the range of 1~4.
9. Press TIMER ON to confirm.
10. Remove the remote controller battery, and then re-insert the battery
after the remote controller screen goes blank. The remote controller
exits the MODIFICATION mode. After you power OFF the unit,
power the unit ON again and the unit retains the setting value.
Fig. 65 — RG57 Remote Controller
FP
Activate/Disable freeze
protection function
ON/OFF
Turns the unit on or off
MODE
Scrolls through operation
modes as follows:
AUT O
COOL
DR Y
HEA T
FAN
FAN/SLC
Selects fan speeds in the
following order:
AUT O
LOW
MED
HIGH
SLEEP
Saves energy during
Hold down this button for
2 seconds to activate the
Silence function.
sleeping hours
TURBO
Enables unit to reach
preset temperature in
shortest possible time
TEMP
Increases temperature in
O
1 F (1
°C)
increments
Max. temperature is
O
86 F
TEMP
Decr
eases temperature in
O
1F (1
°C) increments
Min. temperature is
O
62 F
TIMER ON
Sets timer to turn unit on
TIMER OFF
Sets timer to turn unit off
SWING/DIRECT
Starts and stops up-down
airflow louver movement
LED
Turns indoor unit s LED display on and off.
,
FOLLOW ME
Temperature sensing
and room temperature
display button
SELF CLEAN
Starts and stops
self clean feature
ON/OFF
TEMP
FP
TIMER
ON
TIMER
OFF
MODE
FAN/SLC
SLEEP
TURBO
SWING
DIRECT
CLEAN
LED
FOLLOW
If you are sensitive to light when you go to
sleep, you can press the LED button to turn
off the LED display on the indoor unit. Press
the button again to turn it back on
NOTE: Press and hold
and buttons
together for 3 seconds to
alternate the temperature
display between the
OO
C & F scale