AIR CONDITIONER FEATURES
If the unit breaks off unexpectedly due to the power 
cut, it will restart with the previous function setting 
automatically when the power resumes. 
DISPLAYS:
NOTE:
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, 
here are more features in your control that you should 
become familiar with.
    The Cool circuit has an automatic 3 minutes time 
    delayed start if the unit is turned off and on quickly. 
    This prevents overheating of the compressor and 
    possible circuit breaker tripping.The fan will 
    continue to run during this time.
    The control is capable of displaying temperature in 
    degrees Fahrenheit or degrees Celsius. To convert 
    from one to the other, press and hold the Up and 
    Down  buttons at the same time f
or 3 seconds.
CARE AND CLEANING
CAUTION
Clean your air conditioner occasionally to keep it looking 
new. Be sure to unplug the unit before cleaning to 
prevent shock or fire hazards.
Air Filter Cleaning
 
For 5000 to 6000 Btu/h
For 6000 to 12000 Btu/h
Remove the filter by 
sliding out from the 
right-hand side.
O O
Shows the set temperature in "  C" or "  F" and the
Auto-timer settings.While on Fan only mode,it shows 
the room temperature. If the room temperature is too
high or low, it will display " HI" or " LO" .  
DISPLAYS:
      -Evaporator temperature sensor error
 
NOTE:  " " is displayed as shown in the obove picture. 
HS -Electric heating sensor error(on some models);
CS -Condenser temperature sensor error(on some 
        models);
OS -Outside temperature sensor error(on some models);
E7  -Unit malfunction(on some models).
NOTE:When error occurs,unplug the u
nit and plug 
            it back in.If error repeats, call for service.
 
 
Error codes:
AS -Room temperature sensor error
 
ES
or 
Displays
21