F2
3 O Open or short circuit of T3 temperature sensor
F3 4 O Open or short circuit of T5 temperature sensor
F4 5 O Outdoor EEPROM malfunction
F6 7 O Open or short circuit of T2B temperature sensor
P0
1
IPM module protection or IGBT over-strong current
protection
P1 2
Over voltage or too low voltage protection
P2 3
Temperature protection of compressor top
P4 5
Inverter compressor drive protection
P5 6
Mode conflict
O light X off flash
Cassette series:
Operation Timer De-frost Alarm LED STATUS
X X X Open or short circuit of T1 temperature sensor
X X
X Open or short circuit of T2 temperature sensor
X
X X Indoor / outdoor units communication error
X X X
Full-water malfunction
X X Indoor EEPROM malfunction
X X
IPM module protection
X X Open or short circuit of T3 or T4 temperature sensor
X
Outdoor voltage protection
Temperature protection of compressor top
X
Mode conflict
X Inverter compressor drive protection
flash, light, X extinguished.
Ceiling &Floor series:
Operation Timer De-frost Alarm LED STATUS
X X X Open or short circuit of T1 temperature sensor
X X
X Open or short circuit of T2 temperature sensor
X
X X Indoor / outdoor units communication error
X X X
Full-water malfunction
X X Indoor EEPROM malfunction
X X
IPM module protection
X X Open or short circuit of T3 or T4 temperature sensor
X
Outdoor voltage protection
X
X Temperature protection of compressor top
X
Mode conflict
flash, light, X extinguished.