Do you have a question about the Midea M5OA-36HRDN1-Q and is the answer not in the manual?
The hydrophilic fin can improve the heating efficiency at operation mode.
It is only operated in the heating operation mode except defrosting operation.
It protects the valves and prevents water from dripping.
Wiring diagram for M2OC-14HRDN1-Q model.
Wiring diagram for M2OC-14HRDN1 model.
Wiring diagram for M2OC1-18HRDN1-Q model.
Wiring diagrams for M3OC1-21HRDN1-Q, M3OC1-27HRDN1-Q, M3OC-27HRDN1 models.
Wiring diagram for M2OC-18HRDN1 model.
Wiring diagram for M4OC-24HRDN1-Q model.
Wiring diagrams for M4OC1-27HRDN1-Q and M4OC-27HRDN1 models.
Wiring diagram for M4OC-36HRDN1-Q model.
Wiring diagram for M50A-36HRDN1-Q model.
Diagram of binary type refrigeration circuit.
Diagram of trinary type refrigeration circuit.
Diagram of quadplex type refrigeration circuit.
Diagram of quintuple type refrigeration circuit.
Combinations for M2OC-14HRDN1-Q and M2OC-14HRDN1 models.
Combinations for M2OC1-18HRDN1-Q and M2OC-18HRDN1 models.
Combinations for M3OC1-21HRDN1-Q models.
Combinations for M3OC1-27HRDN1-Q and M3OC-27HRDN1 models.
Combinations for M4OC-24HRDN1-Q models.
Combinations for M4OC1-27HRDN1-Q and M4OC-27HRDN1 models.
Combinations for M4OC-36HRDN1-Q models.
Combinations for M5OA-36HRDN1-Q models.
Defines abbreviations used for temperature sensors and settings.
Specifies voltage, frequency, and current limits for operation.
Explains the display functions of the outdoor unit's LED.
Details how to check unit states using SW1.
Explains how opening degree relates to display data.
Specifies the delay before compressor restart.
Describes limits for compressor discharge temperature.
Details voltage limits for protection.
Explains frequency limits based on current.
Describes protection if communication is lost.
Protection triggered by high condenser coil temperature.
Protection against outdoor unit freezing.
Rules for oil return operation.
Conditions and modes for compressor preheating.
Operation of the compressor crankcase heater.
Explains error codes for indoor units.
Explains error codes for outdoor units.
Troubleshooting steps for indoor EEPROM errors.
Troubleshooting steps for communication errors.
Troubleshooting steps for zero-crossing signal errors.
Troubleshooting steps for indoor fan speed issues.
Troubleshooting for temperature sensor faults.
Troubleshooting steps for full-water errors.
Troubleshooting for outdoor EEPROM errors.
Troubleshooting steps for compressor voltage protection.
Troubleshooting for IPM/main board communication issues.
Troubleshooting for compressor discharge temperature protection.
Troubleshooting for compressor top temperature protection.
Troubleshooting steps for high-pressure protection.
Troubleshooting steps for low-pressure protection.
Troubleshooting for compressor current protection.
Troubleshooting steps for IPM module protection.
Troubleshooting for high condenser temperature protection.
Troubleshooting steps for PFC module protection.
Troubleshooting for inverter compressor drive protection.