35
★

X X
Outdoor temperature sensor(coil
sensor T3 or ambient temperature
sensor T4) malfunction or
Outdoor unit EEPROM parameter
E6 E0,E4
★

★
X Outdoor fan speed malfunction E7 E8
★
 
X Indoor fan speed malfunction F5 ——
★

X

Over-voltage or under-voltage
protection
P0 E5
★ ★ ★
X Current overload protection P2 P3
★ ◎
X X Compressor drive malfunction P4 ——
★
X
 
Indoor units mode conflict P5 ——
★ flash at 2.5Hz,  light, X extinguished, , ◎flash at 0.5Hz
For Old Vertu/Luna Series
Indoor unit EEPROM parameter error E0
★
Communication malfunction between indoor
and outdoor units error
E1

Zero-crossing signal detection error E2

Indoor fan speed malfunction E3
X

X
★
Outdoor temperature sensor(coil sensor T3
or ambient temperature sensor T4)
malfunction or Outdoor unit EEPROM
E5

★
Indoor room temperature sensor(room sensor
T1 or coil sensor T2) malfunction
Outdoor fan speed malfunction E7
X
★
Inverter module (IPM) malfunction P0
X

★
Over-voltage or under-voltage protection P1

★
Compressor top high temperature protection
(OLP)
P2

★
Low ambient temperature cut off in heating P3

Compressor drive malfunction P4
X

Indoor units mode conflict P5
For All new models(New Wall mounted(Hi-Wall) series, New Duct/Cassette/Console/Floor
Ceiling):
Operation
lamp
Timer
lamp
Display LED STATUS
Error
★ 1 time
X E0 Indoor unit EEPROM parameter error