EasyManua.ls Logo

Midea MCH3U-27PHH2

Midea MCH3U-27PHH2
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
8.2 Indoor Unit Error Display
For Old Console series
Operation
Timer
De-
frost
Failure
X X Indoor room temperature sensor (T1 ) malfunction
X X
Evaporator coil temperature sensor (T2) malfunction
X
X Communication malfunction between indoor and outdoor units
X Low ambient temperature cut off in heating
X Indoor unit EEPROM parameter error
X
Outdoor fan speed malfunction
X
Inverter module (IPM) malfunction
Outdoor temperature sensor(coil sensor T3 or ambient
temperature sensor T4) malfunction or Outdoor unit EEPROM
parameter error
X Compressor top high temperature protection (OLP)
X Compressor drive protection
X
Indoor units mode conflict
Indoor fan speed malfunction
X X
In standby mode
In force cooling mode
flash at 5Hz, light, X extinguished, flash at 0.5Hz
For Old Duct/Cassette/Floor Ceiling
Operatio
n
Time
r
De-
frost
Alar
m
Failure
Display
ODU Error
code
X X X
Indoor room temperature sensor
(T1 ) malfunction
E0 ——
X X
X
Evaporator coil temperature
sensor (T2) malfunction
E1 ——
X
X X
Communication malfunction
between indoor and outdoor units
E2 E2
X X X
Water-level alarm malfunction E3 ——
X X
Indoor unit EEPROM parameter
error
E4 ——
X X
Inverter module (IPM) malfunction
E5 P6

Related product manuals