8.4.2.6 E6 (PFC module protection) error diagnosis and solution.
Error Code
E6
Malfunction
conditions
When the voltage signal that PFC sends to main control board
is abnormal, the display LED will showE6” and AC will turn
off.
Potential causes
Wiring mistake
Faulty outdoor PCB
Faulty inductance of PFC module
PFC module malfunction
Trouble shooting: