34
8.2 Indoor Unit Error Display
For Old Console series
Operation
Timer
De-
frost
Failure
X X Indoor room temperature sensor (T1 ) malfunction
X X
Evaporator coil temperature sensor (T2) malfunction
X
X Communication malfunction between indoor and outdoor units
X Low ambient temperature cut off in heating
X Indoor unit EEPROM parameter error
X
Outdoor fan speed malfunction
X
Inverter module (IPM) malfunction
Outdoor temperature sensor(coil sensor T3 or ambient
temperature sensor T4) malfunction or Outdoor unit EEPROM
parameter error
X Compressor top high temperature protection (OLP)
X Compressor drive protection
X
Indoor units mode conflict
Indoor fan speed malfunction
X X
In standby mode
In force cooling mode
flash at 5Hz, light, X extinguished, flash at 0.5Hz
For Old Duct/Cassette/Floor Ceiling
Operatio
n
Time
r
De-
frost
Alar
m
Failure
Display
ODU Error
code
X X X
Indoor room temperature sensor
(T1 ) malfunction
E0 ——
X X
X
Evaporator coil temperature
sensor (T2) malfunction
E1 ——
X
X X
Communication malfunction
between indoor and outdoor units
E2 E2
X X X
Water-level alarm malfunction E3 ——
X X
Indoor unit EEPROM parameter
error
E4 ——
X X
Inverter module (IPM) malfunction
E5 P6