Wiring MCAC-UTSM-2009-03
52 Installation
2. Dissemble the bolts from the cover. (If there isn't a cover on the outdoor unit, disassemble the bolts from
the maintenance board, and pull it in the direction of the arrow to remove the protection board.)
3. Connect the connective cables to the terminals as identified with their respective matched numbers on
the terminal block of indoor and outdoor units.
4. Re-install the indoor unit and outdoor unit.
6.2.2 The Specification of Power
Type 12000Btu/h 18000Btu/h
Power
Phase 1-phase 1-phase
Frequency and Voltage 220-240V, 50Hz 220-240V, 50Hz
Circuit Breaker/ Fuse (A) 20/16 20/16
Indoor Unit Power Wiring (mm
2
) 3×1.5 3×2.5
Indoor/Outdoor Connecting Wiring (mm
2
)
Ground Wiring 1.5 2.5
Outdoor Unit Power Wiring
Strong Electric Signal 4×1.5 4×2.5